Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2027622
Status: Active
Facility Name: Flyers Energy, LLC d/b/a Quick Fuel #3144
Address: 715 W. 172nd Street South Holland, IL 60473
County: Cook
Property Parcel: 29-28-100-082-0000
Facility Type: Unattended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003736
Green Tag Issue Date: 1/29/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Pals Group, LLC
Owner Address: 1617 Rietveld Drive Crete, IL 60417
Owner Status: Current Owner
Purchase Date: 8/17/2001
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 3/31/2027

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Unattended Self Service 1/29/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041539 Pals Group, LLC Current Owner 8/17/2001
U0029778 Jacobus Energy, Inc. Former Owner
U0016986 Quick Fuel Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251447 (Referred to Legal)    Issue Date: 6/5/2025    Expiration Date: 8/4/2025    View NOV Form

Tanks Violations
2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Both STP's are missing lids for containments and the Regular tank STP containment is cracked on top of contianment. Repair/Replace.
Facility Facility Operation and Maintenance Plan not completed or available. - Facility Operations and Maintenance Plan does not meet requirements of new rules or is not available. Form and be found at https://sfm.illinois.gov/content/dam/soi/en/web/sfm/sfmdocuments/documents/oandmtemplate.pdf to download and complete O & M template and maintain completed form on site.
1, 2 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - (Both STP's)

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
01-0936 Eligible 8/1/2001 8/17/2001 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/15/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 6/13/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/20/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/21/2025 1/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/21/2025 1/21/2026
Overfill Prev Device Overfill Alarm 10/2/2024 10/2/2027
Overfill Prev Device Overfill Drop Tube Valve 10/2/2024 10/2/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 8/14/2025 8/14/2028
Leak Detect - Piping Discriminating Sump Sensor 3/29/2019 3/29/2020
Leak Detect - Piping Sump Sensor 1/21/2025 1/21/2026
Spill Contain Device Double Wall Spill Bucket 11/28/2023 11/28/2026
Tank Fiberglass Single Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 1/21/2025



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/15/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 6/13/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/20/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/21/2025 1/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/21/2025 1/21/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/21/2025 1/21/2026
Overfill Prev Device Overfill Alarm 10/2/2024 10/2/2027
Overfill Prev Device Overfill Drop Tube Valve 10/2/2024 10/2/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 11/28/2023 11/28/2026
Leak Detect - Piping Discriminating Sump Sensor 3/29/2019 3/29/2020
Leak Detect - Piping Sump Sensor 1/21/2025 1/21/2026
Spill Contain Device Single Wall Spill Bucket 11/28/2023 11/28/2026
Tank Fiberglass Double Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 1/21/2025

Dispenser Information



Name\ID 1M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 1S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 2M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 2S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 4/5

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 6/7

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A