Facility Details

Facility Number: 2027394
Status: Active
Facility Name: BP Amoco #2254
Address: 550 North Route 83 & Foster Bensenville, IL 60106
County: Du Page
Property Parcel: 03-10-421-005
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003395
Green Tag Issue Date: 5/23/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Hemant Patel
Owner Address: 3 Deveaux Court South Barrington, IL 60634
Owner Status: Current Owner
Purchase Date: 9/2/2008
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/28/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/23/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034964 Patel, Hemant Current Owner 9/2/2008
U0023834 BP Amoco Former Owner 1/1/1990
U0000574 Amoco Oil Company Former Owner 12/31/1967
U0000552 BP Products North America, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251324 (Pending)    Issue Date: 5/21/2025    Expiration Date: 7/20/2025    View NOV Form

Tanks Violations
4, 5, 6 Line interstitial sensors have been raised and rendered inoperational. - Dispenser 3/4 175.640 a) 2) All new and existing sump sensors must be installed so as to detect liquid per manufacturer's specifications or, if not specified by the manufacturer, at the lowest point in the sump.
5 Line leak detection equipment in alarm or failed test, must repair or replace. - Tank 5 STP sump sensor failed annual testing. Repair or replace sensor and enter passing results on OSFM portal.
5 Miscellaneous - Vapor adaptor is broken on drop tube.
6 Miscellaneous - Premium vapor cap is broken.
7 Miscellaneous - ATG shows 8 gallons .97" of water in tank.
4, 5, 6, 7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - 175.405 a) 1) A) Spill containment equipment that will prevent release of product to the environment when the transfer hose is detached from the fill pipe (e.g., a spill catch basin). Spill containment equipment shall be maintained in a dry, clean state.
4, 5, 6, 7 Tank monitor does not appear to function properly and requires maintenance. - Green indicator light is out. Repair so light is lit.
4, 5, 6 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - Dispenser 3/4

NOV Number: E0020251327 (Pending)    Issue Date: 5/21/2025    Expiration Date: 7/20/2025    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Dispenser 9/10 doesn't work 175.210 h)The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
01-0716 4/25/2001 Removal Log 01727-2000REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
01-0716 Eligible 6/3/2004 6/21/2004 $10,000
Pay Tank Fees Online

Tank Information

Tank Number Capacity Product Status Regulated Status Red Tag Issued Fee Due Abandon/Removal Date
1 12000 Gasoline Removed Federal $0.00 04/25/2001 - REM
2 12000 Gasoline Removed Federal $0.00 04/25/2001 - REM
3 12000 Gasoline Removed Federal $0.00 04/25/2001 - REM
4 12000 Gasoline - Regular Currently in use Federal $0.00
5 12000 Gasoline - Regular Currently in use Federal $0.00
6 12000 Gasoline - Premium Currently in use Federal $0.00
7 6000 Diesel Fuel Currently in use Federal $0.00

Dispenser Information

Name\ID Status
1/2 Active
11/12 Active
13/14 Active
3/4 Active
5/6 Active
7/8 Active
9/10 Active

MFD Motorfuel Dispensing Forms

No Forms Found