Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2025082
Status: Active
Facility Name: Posen Gas & Food
Address: 2700 W. 147th Street Posen, IL 60469
County: Cook
Property Parcel: 28-12-225-073-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002625
Green Tag Issue Date: 3/28/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Posen Property Group, LLC
Owner Address: 2700 W. 147th St. Posen, IL 60469
Owner Status: Current Owner
Purchase Date: 12/18/2014
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/20/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/9/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037921 Posen Property Group, LLC Current Owner 12/18/2014
U0035176 Daros, Danielle Former Owner 12/1/2008
U0005658 Gas City, Ltd. Former Owner 6/1/1996
U0003821 Daros John Former Owner 12/31/1967
U0036250 First Choice Gas II, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
11-0732 7/7/2011 Removal Log 00542-2011REM
18-0381 5/16/2018 Removal Log 00525-2018REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20180381 Eligible 6/25/2018 7/9/2018 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/16/2018
OSFM First Notify Date: 2/6/1990 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1978

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/9/2017 5/9/2018
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/9/2017 5/9/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/16/2018
OSFM First Notify Date: 2/6/1990 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1978

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/9/2017 5/9/2018
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/9/2017 5/9/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/16/2018
OSFM First Notify Date: 2/6/1990 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1978

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/9/2017 5/9/2018
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/9/2017 5/9/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 2000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/10/1997 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 12/24/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/22/2025 2/22/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/22/2025 2/22/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/22/2025 2/22/2026
Overfill Prev Device Overfill Drop Tube Valve 12/28/2023 12/28/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 12/15/2022 12/15/2025
Leak Detect - Piping Sump Sensor 2/22/2025 2/22/2026
Spill Contain Device Single Wall Spill Bucket 3/22/2023 3/22/2026
Tank Composite Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 2/22/2025



Tank Number 5

Capacity: 500 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 7/7/2011
OSFM First Notify Date: 6/21/2011 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 500 Petroleum Use:
Product: Waste Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 7/7/2011
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/1/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 5/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/22/2025 2/22/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 2/22/2025 2/22/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/22/2025 2/22/2026
Overfill Prev Device Overfill Drop Tube Valve 3/22/2023 3/22/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 12/15/2022 12/15/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/22/2025 2/22/2026
Spill Contain Device Single Wall Spill Bucket 12/15/2022 12/15/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/22/2025



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/1/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 5/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/22/2025 2/22/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 3/17/2025 3/17/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/22/2025 2/22/2026
Overfill Prev Device Overfill Drop Tube Valve 12/15/2022 12/15/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 12/15/2022 12/15/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/22/2025 2/22/2026
Spill Contain Device Single Wall Spill Bucket 12/15/2022 12/15/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/22/2025



Tank Number 9

Capacity: 4000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/1/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 5/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/22/2025 2/22/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 2/22/2025 2/22/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/22/2025 2/22/2026
Overfill Prev Device Overfill Drop Tube Valve 3/22/2023 3/22/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 12/15/2022 12/15/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/22/2025 2/22/2026
Spill Contain Device Single Wall Spill Bucket 12/15/2022 12/15/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/22/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/15/2022 12/15/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/22/2025 2/22/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/15/2022 12/15/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/22/2025 2/22/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/15/2022 12/15/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/22/2025 2/22/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/15/2022 12/15/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/22/2025 2/22/2026

MFD Motorfuel Dispensing Forms

No Forms Found