Facility Details
Facility Number:
2024943
Status:
Closed
Facility Name:
Snyders Mobil Service
Address:
28841 Roberts Rd. Port Barrington, IL 60010
County:
Lake
Property Parcel:
Facility Type:
Full Service Station
Owner Type:
Private
Green Tag Decal:
M000210
Green Tag Issue Date:
1/10/2011
Green Tag Expiration Date:
12/31/2013
Owner Details
Owner Name:
Michael Blazincic
Owner Address:
28841 Roberts Rd. Port Barrington, IL 60010
Owner Status:
Current Owner
Purchase Date:
1/1/1968
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
7/16/2014
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Fleet
1/10/2011
12/31/2013
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0001642
Blazincic , Michael
Current Owner
1/1/1968
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
13-0905
8/14/2013
Removal Log
00700-2013REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
13-0905
Returned
9/4/2013
10/21/2013
$5,000
13-0905
Eligible
11/12/2013
11/14/2013
$5,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
1000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/14/2013
OSFM
First Notify Date:
6/7/1989
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
1/1/1978
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/10/1978
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
2/26/2008
2/26/2013
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik Jr.
Overfill Prev Device
Overfill Alarm
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
1000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/14/2013
OSFM
First Notify Date:
6/7/1989
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
1/1/1978
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/10/1978
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
2/26/2008
2/26/2013
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik Jr.
Overfill Prev Device
Overfill Alarm
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
500
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/14/2013
OSFM
First Notify Date:
6/7/1989
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
1/1/1978
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/10/1978
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
2/26/2008
2/26/2013
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik Jr.
Overfill Prev Device
Overfill Alarm
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found