Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2024544
Status:
Active
Facility Name:
Bucky's Express #6436
Address:
1185 W. Park Avenue
Libertyville, IL 60048
County:
Lake
Property Parcel:
11-20-200-004
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Z000737
Green Tag Issue Date:
3/20/2024
Green Tag Expiration Date:
12/31/2026
Owner Details
Owner Name:
Casey's Retail Company
Owner Address:
3305 SE Delaware Ave.
P.O. Box 3004
Ankeny, IA 50021
Owner Status:
Current Owner
Purchase Date:
5/14/2021
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
10/27/2025
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
3/20/2024
12/31/2026
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0002560
Casey's Retail Company
Current Owner
5/14/2021
U0036013
Buchanan Energy (N), LLC
Former Owner
12/9/2010
U0010471
Exxon Mobil Oil Corporation
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
02-0606
5/30/2002
Removal Log
00374-2002REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
88-1189
Eligible
8/5/1994
8/24/1994
$50,000
02-0606
Ineligible
3/25/2005
4/25/2005
$Not Selected
88-1189
Eligible
6/27/2011
8/24/2011
$50,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/3/1989
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
8/1/1988
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/1/1988
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Other Non-vented check valve
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
2/10/2025
2/10/2026
Overfill Prev Device
Ball Only Removed Ball Float Vent Valve
N/A
N/A
Overfill Prev Device
Overfill Drop Tube Valve
1/20/2023
1/20/2026
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
2/3/2023
2/3/2026
Leak Detect - Piping
Sump Sensor
2/1/2024
2/1/2025
Leak Detect - Piping
Sump Sensor with positive shutdown
2/10/2025
2/10/2026
Spill Contain Device
Single Wall Spill Bucket
2/3/2023
2/3/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
12/18/2023
Tank Number 2
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/3/1989
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
8/1/1988
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/1/1988
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Other Non-vented check valve
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
2/10/2025
2/10/2026
Overfill Prev Device
Ball Only Removed Ball Float Vent Valve
N/A
N/A
Overfill Prev Device
Overfill Drop Tube Valve
1/20/2023
1/20/2026
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
2/3/2023
2/3/2026
Leak Detect - Piping
Sump Sensor
2/10/2025
2/10/2026
Spill Contain Device
Single Wall Spill Bucket
2/3/2023
2/3/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
12/18/2023
Tank Number 3
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/3/1989
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
8/1/1988
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/1/1988
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
2/10/2025
2/10/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
2/10/2025
2/10/2026
Overfill Prev Device
Ball Only Removed Ball Float Vent Valve
N/A
N/A
Overfill Prev Device
Overfill Drop Tube Valve
1/20/2023
1/20/2026
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
2/3/2023
2/3/2026
Leak Detect - Piping
Sump Sensor
2/10/2025
2/10/2026
Spill Contain Device
Single Wall Spill Bucket
2/3/2023
2/3/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
12/18/2023
Tank Number 4
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/3/1989
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
8/1/1988
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/1/1988
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
2/10/2025
2/10/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
2/10/2025
2/10/2026
Overfill Prev Device
Ball Only Removed Ball Float Vent Valve
N/A
N/A
Overfill Prev Device
Overfill Drop Tube Valve
1/20/2023
1/20/2026
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
2/3/2023
2/3/2026
Leak Detect - Piping
Sump Sensor
2/10/2025
2/10/2026
Spill Contain Device
Single Wall Spill Bucket
2/3/2023
2/3/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/1/1988
OSFM
First Notify Date:
6/23/1994
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1970
Red Tag Issue Date:
Last Used Date:
8/1/1988
Fee Due:
$0.00
Product Date:
1/1/1970
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/1/1988
OSFM
First Notify Date:
6/23/1994
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1970
Red Tag Issue Date:
Last Used Date:
8/1/1988
Fee Due:
$0.00
Product Date:
1/1/1970
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/1/1988
OSFM
First Notify Date:
6/23/1994
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1970
Red Tag Issue Date:
Last Used Date:
8/1/1988
Fee Due:
$0.00
Product Date:
1/1/1970
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
1000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
5/30/2002
OSFM
First Notify Date:
6/10/2002
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/31/1973
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
560
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
5/30/2002
OSFM
First Notify Date:
6/10/2002
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/31/1973
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 10
Capacity:
1000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
5/30/2002
OSFM
First Notify Date:
6/10/2002
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/31/1973
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/3/2023
2/3/2026
Leak Detect - Piping
Sump Sensor
2/10/2025
2/10/2026
Name\ID 11/12
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/3/2023
2/3/2026
Leak Detect - Piping
Sump Sensor
2/10/2025
2/10/2026
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/3/2023
2/3/2026
Leak Detect - Piping
Sump Sensor
2/10/2025
2/10/2026
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/3/2023
2/3/2026
Leak Detect - Piping
Sump Sensor
2/10/2025
2/10/2026
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/3/2023
2/3/2026
Leak Detect - Piping
Sump Sensor
2/10/2025
2/10/2026
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
2/3/2023
2/3/2026
Leak Detect - Piping
Sump Sensor
2/10/2025
2/10/2026
MFD
Motorfuel Dispensing Forms