Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2024384
Status: Active
Facility Name: IL-0085
Address: 847 N. Sheridan Rd. Winthrop Harbor, IL 60096
County: Lake
Property Parcel: 04-10-116-008
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00822
Green Tag Issue Date: 1/14/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Lehigh Gas Wholesale Services
Owner Address: 645 Hamilton, Suite 400 Allentown, PA 18101
Owner Status: Current Owner
Purchase Date: 9/27/2016
Type of Financial Responsibility: Surety Bond
Financial Responsibility Reporting Due Date: 6/6/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/14/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037337 Lehigh Gas Wholesale Services Current Owner 9/27/2016
U0000651 B.A.P.A., LLC & PT, LLC Former Owner 10/23/2014
U0024983 Clark Refining & Marketing, Inc. Former Owner 10/25/1994
U0025164 BAPA, LLC & PT, LLC Former Owner
U0031486 The Premcor Refining Group, Inc.. Former Owner
U0031551 SLM Development of Winthrop Harbor Inc. Former Owner
U0029789 Clark Retail Enterprises, Inc. Former Owner
U0028787 Clark Retail Enterprises, Inc., Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00800-2025ABN Abandon in Place Approved / Issued 6/27/2025 6/27/2025 12/29/2025 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
96-0428 Eligible 7/19/1996 7/31/1996 $10,000
99-0520 Eligible 3/14/2003 3/27/2003 $10,000
96-0428 Eligible 5/20/2003 6/18/2003 $10,000
96-0428 Eligible 5/19/2008 6/17/2008 $10,000
99-0520 Eligible 2/19/2009 3/11/2009 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/6/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 4/29/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/29/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/31/2024 5/31/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/7/2025 4/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/7/2025 4/7/2026
Overfill Prev Device Overfill Drop Tube Valve 4/16/2024 4/16/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 7/11/2024 7/11/2027
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 10/28/2024 10/28/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/7/2025
Piping Steel Single Wall Piping Precision Test (Piping) Pass 4/7/2025



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/6/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 4/29/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/29/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/31/2024 5/31/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/31/2024 5/31/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/7/2025 4/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/7/2025 4/7/2026
Overfill Prev Device Overfill Drop Tube Valve 5/16/2024 5/16/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 10/21/2024 10/21/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/7/2025
Piping Steel Single Wall Piping Precision Test (Piping) Pass 4/7/2025



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/6/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 4/29/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/29/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/31/2024 5/31/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/31/2024 5/31/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/7/2025 4/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/7/2025 4/7/2026
Overfill Prev Device Overfill Drop Tube Valve 4/17/2024 4/17/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/21/2024 10/21/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/7/2025
Piping Steel Single Wall Piping Precision Test (Piping) Pass 4/7/2025



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Racing Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/6/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 37 Abandoned Date: 7/8/2025
Install Date: 4/29/1988 Red Tag Issue Date:
Last Used Date: 5/1/2024 Fee Due: $0.00
Product Date: 4/29/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/31/2024 5/31/2025
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 5/31/2024 5/31/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/16/2024 4/16/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/7/2025 4/7/2026
Overfill Prev Device Overfill Drop Tube Valve 4/17/2024 4/17/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/21/2024 10/21/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/16/2024
Piping Steel Single Wall Piping Precision Test (Piping) Pass 4/16/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 1/30/2023



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/6/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 4/29/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/29/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/31/2024 5/31/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/31/2024 5/31/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/7/2025 4/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/7/2025 4/7/2026
Overfill Prev Device Overfill Drop Tube Valve 4/16/2024 4/16/2027
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 10/21/2024 10/21/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/16/2024
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test (Piping) Pass 3/30/2020
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test (Piping) Pass 4/7/2025
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/18/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 13 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 14 RACING GA

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found