Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0041258 |
6777 Lincoln Real Estate, Inc. |
Current Owner |
7/16/2024 |
| U0002560 |
Casey's Retail Company |
Former Owner |
5/14/2021 |
| U0036013 |
Buchanan Energy (N), LLC |
Former Owner |
12/9/2010 |
| U0010471 |
ExxonMobil Oil Corporation |
Former Owner |
|
Permits (Unexpired)
Click for permit history
| Permit Number |
Type |
Status |
OSFM Receive Date |
Issue Date |
Expiration Date |
Documents |
| 00761-2026CAT |
Cathodic Protection |
Approved / Issued |
7/1/2026 |
7/1/2026 |
1/2/2027 |
Documents |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 01-1070 |
Eligible |
10/1/2001
|
10/17/2001
|
$10,000
|
|
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/17/1986 |
|
Abandoned Material: |
|
| Current Age: |
39 |
|
Abandoned Date: |
|
| Install Date: |
10/1/1986 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
7/1/2026 |
7/1/2027 |
|
Leak Detect - Piping
|
Siphon Bar |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
7/1/2026 |
7/1/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/25/2025 |
6/25/2028 |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/25/2025 |
6/25/2028 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L
|
Precision Test (Piping)
|
Pass
|
7/1/2026
|
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/17/1986 |
|
Abandoned Material: |
|
| Current Age: |
39 |
|
Abandoned Date: |
|
| Install Date: |
10/1/1986 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Siphon Bar |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
7/1/2026 |
7/1/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/25/2025 |
6/25/2028 |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/25/2025 |
6/25/2028 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Piping
|
Siphon Bar
|
Functional
|
Pass
|
6/25/2025
|
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L
|
Precision Test (Piping)
|
Pass
|
7/1/2026
|
Tank Number 3
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/17/1986 |
|
Abandoned Material: |
|
| Current Age: |
39 |
|
Abandoned Date: |
|
| Install Date: |
10/1/1986 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
7/1/2026 |
7/1/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
7/1/2026 |
7/1/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/25/2025 |
6/25/2028 |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/25/2025 |
6/25/2028 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L
|
Precision Test (Piping)
|
Pass
|
7/1/2026
|
Tank Number 4
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/17/1986 |
|
Abandoned Material: |
|
| Current Age: |
39 |
|
Abandoned Date: |
|
| Install Date: |
10/1/1986 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
7/1/2026 |
7/1/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
7/1/2026 |
7/1/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/25/2025 |
6/25/2028 |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/25/2025 |
6/25/2028 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L
|
Precision Test (Piping)
|
Pass
|
7/1/2026
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/2
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
2/4/2026
|
2/4/2029
|
Name\ID 11/12
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
2/4/2026
|
2/4/2029
|
Name\ID 3/4
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
2/4/2026
|
2/4/2029
|
Name\ID 5/6
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
2/4/2026
|
2/4/2029
|
Name\ID 7/8
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
2/4/2026
|
2/4/2029
|
Name\ID 9/10
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
2/4/2026
|
2/4/2029
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found