Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2023545
Status: Active
Facility Name: Verizon
Address: 9060 S. Archer Ave. Willow Springs, IL 60480
County: Cook
Property Parcel: 23-05-201-032-0000
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: BB03698
Green Tag Issue Date: 5/14/2026
Green Tag Expire Date: 12/31/2028
MFD Type: N/A

Owner Details

Owner Name: MCI d/b/a Verizon Business
Owner Address: 2 Hampshire St. Lawrence, MA 01840
Owner Status: Current Owner
Purchase Date: 3/1/1990
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/29/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0022133 MCI d/b/a Verizon Business Current Owner 3/1/1990
U0010000 MCI Telecommunications Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 7/1/1986
OSFM First Notify Date: 7/10/1986 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/19/1994
OSFM First Notify Date: 9/24/1993 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 3/1/1990 Red Tag Issue Date:
Last Used Date: 4/19/1994 Fee Due: $0.00
Product Date: 3/1/1990

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 10000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/24/1993 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 12/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1989

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Pneumercator TMS 2000 11/11/2025 11/11/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 11/11/2025 11/11/2026
Overfill Prev Device Overfill Alarm 11/11/2025 11/11/2028
Overfill Prev Device Overfill Drop Tube Valve 11/11/2025 11/11/2028
Piping Flexible Double Wall Environ Geo Flex Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated 11/12/2025 Not applicable
Piping Single Wall Transition Sump 11/12/2025 No passing test found
Spill Contain Device Single Wall Spill Bucket 11/12/2025 11/12/2028
Tank Fiberglass Double Wall Owens Corning Not applicable Not applicable
Vent, Riser, Fill Piping Non-corrosive Environ Geo Flex flexible vent line Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 11/11/2025



Tank Number 4

Capacity: 5000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/6/1993
OSFM First Notify Date: 9/24/1993 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 6/1/1983 Red Tag Issue Date:
Last Used Date: 12/6/1993 Fee Due: $0.00
Product Date: 7/1/1983

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found