Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2022847
Status: Active
Facility Name: Skokie BP (SS# 143)
Address: 5035 Touhy Avenue Skokie, IL 60077
County: Cook
Property Parcel:
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: Z002429
Green Tag Issue Date: 10/18/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Graham Enterprise, Inc.
Owner Address: 750 Bunker Court Vernon Hills, IL 60061
Owner Status: Current Owner
Purchase Date: 4/27/2009
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0023084 Graham Enterprise, Inc. Current Owner 4/27/2009
U0023834 BP Amoco Former Owner 1/1/1992
U0000552 BP Products North America, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261350 (Pending)    Issue Date: 5/21/2026    Expiration Date: 7/20/2026    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shut off switch needs annual testing performed. OSFM form shall be kept on site.
5, 6, 7 Annual leak detection certification not completed (Required annually).
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual walkthrough needs to be performed. OSFM form shall be completed and kept on site.
5, 6, 7 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Shear valves need annual testing performed. OSFM form shall be completed and kept on site.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
01-0669 5/25/2001 Removal Log 00891-2001REM
01-1553 9/17/2001 Removal Log 00891-2001REM
89-0995 6/23/1992 Removal Log 4553-92

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
01-1553 Eligible 8/4/2016 8/8/2016 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/17/2001
OSFM First Notify Date: 8/31/1992 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 2/23/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/23/1992
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/1/1965 Red Tag Issue Date:
Last Used Date: 6/23/1992 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/23/1992
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/1/1965 Red Tag Issue Date:
Last Used Date: 6/23/1992 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/23/1992
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: 6/23/1992 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/27/1996 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 6/24/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/24/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/4/2024 9/4/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/4/2024 9/4/2027
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/14/2025 5/14/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/14/2025 5/14/2026
Overfill Prev Device Overfill Drop Tube Valve 5/14/2025 5/14/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/14/2025 5/14/2028
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 5/14/2025



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/27/1996 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 6/24/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/24/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/4/2024 9/4/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/4/2024 9/4/2027
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/14/2025 5/14/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/14/2025 5/14/2026
Overfill Prev Device Overfill Drop Tube Valve 5/14/2025 5/14/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/14/2025 5/14/2028
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 5/14/2025



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/27/1996 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 6/24/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/24/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/4/2024 9/4/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/4/2024 9/4/2027
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/14/2025 5/14/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/14/2025 5/14/2026
Overfill Prev Device Overfill Drop Tube Valve 5/14/2025 5/14/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/14/2025 5/14/2028
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 5/14/2025



Tank Number 8

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/27/1996 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 6/24/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/10/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/4/2024 9/4/2027
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/4/2024 9/4/2027
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank 110 - 600 gallons Manual Tank Gauging N/A N/A
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/14/2025 5/14/2028
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 5/5/2022
Tank STIP3 Single Wall Precision Test (Tank) Pass 5/14/2025



Tank Number 9

Capacity: 500 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/17/2001
OSFM First Notify Date: 10/26/2001 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms