Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2022803
Status:
Active
Facility Name:
Northlake Petroleum
Address:
4804 W. Butterfield Hillside, IL 60162
County:
Cook
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA00189
Green Tag Issue Date:
4/23/2025
Green Tag Expiration Date:
12/31/2027
Owner Details
Owner Name:
Northlake Petroleum
Owner Address:
4804 Butterfield Rd Hillside, IL 60162
Owner Status:
Current Owner
Purchase Date:
6/26/2008
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
5/22/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
3/14/2025
12/31/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0034816
Northlake Petroleum
Current Owner
6/26/2008
U0023834
BP Amoco
Former Owner
4/7/1995
U0027493
Amoco Oil Company
Former Owner
1/1/1991
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
06-0476
4/19/2006
Removal Log
00231-2006REM
91-2752
10/30/1991
Removal Log
1050-91
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
91-2979
Eligible
9/20/1993
11/29/1993
$15,000
06-0476
Eligible
3/16/2007
4/2/2007
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
500
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/9/1991
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
22
Abandoned Date:
Install Date:
1/1/1969
Red Tag Issue Date:
Last Used Date:
10/1/1991
Fee Due:
$0.00
Product Date:
1/1/1969
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/9/1991
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
22
Abandoned Date:
Install Date:
1/1/1969
Red Tag Issue Date:
Last Used Date:
10/1/1991
Fee Due:
$0.00
Product Date:
1/1/1969
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/9/1991
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
22
Abandoned Date:
Install Date:
1/1/1969
Red Tag Issue Date:
Last Used Date:
10/1/1991
Fee Due:
$0.00
Product Date:
1/1/1969
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/9/1991
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
22
Abandoned Date:
Install Date:
1/1/1969
Red Tag Issue Date:
Last Used Date:
10/1/1991
Fee Due:
$0.00
Product Date:
1/1/1969
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
10/30/1991
OSFM
First Notify Date:
3/23/1993
Abandoned Material:
Current Age:
41
Abandoned Date:
Install Date:
1/1/1950
Red Tag Issue Date:
Last Used Date:
1/1/1969
Fee Due:
Product Date:
1/1/1950
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
10/30/1991
OSFM
First Notify Date:
3/23/1993
Abandoned Material:
Current Age:
41
Abandoned Date:
Install Date:
1/1/1950
Red Tag Issue Date:
Last Used Date:
1/1/1969
Fee Due:
Product Date:
1/1/1950
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
12000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/19/2006
OSFM
First Notify Date:
3/23/1993
Abandoned Material:
Current Age:
14
Abandoned Date:
Install Date:
11/1/1991
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/1/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
12000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/19/2006
OSFM
First Notify Date:
3/23/1993
Abandoned Material:
Current Age:
14
Abandoned Date:
Install Date:
11/1/1991
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/1/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
12000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/19/2006
OSFM
First Notify Date:
3/23/1993
Abandoned Material:
Current Age:
14
Abandoned Date:
Install Date:
11/1/1991
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/1/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 10
Capacity:
550
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/19/2006
OSFM
First Notify Date:
3/23/1993
Abandoned Material:
Current Age:
14
Abandoned Date:
Install Date:
11/1/1991
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/1/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 11
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/20/2009
Abandoned Material:
Current Age:
16
Abandoned Date:
Install Date:
5/14/2009
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Composite Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
3/20/2025
3/20/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus
3/20/2025
3/20/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
3/20/2025
3/20/2026
Overfill Prev Device
Overfill Drop Tube Valve
4/8/2024
4/8/2027
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/20/2025
3/20/2028
Leak Detect - Piping
Sump Sensor
3/20/2025
3/20/2026
Spill Contain Device
Single Wall Spill Bucket
3/20/2025
3/20/2028
Tank
Composite Double Wall Lannon
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
3/20/2025
Tank
Composite Double Wall Lannon
Precision Test (Tank)
Pass
3/27/2020
Tank Number 12
Capacity:
8000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/20/2009
Abandoned Material:
Current Age:
16
Abandoned Date:
Install Date:
5/14/2009
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Composite Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
3/20/2025
3/20/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus
3/20/2025
3/20/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
3/20/2025
3/20/2026
Overfill Prev Device
Overfill Drop Tube Valve
4/18/2024
4/18/2027
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/20/2025
3/20/2028
Leak Detect - Piping
Sump Sensor
3/20/2025
3/20/2026
Spill Contain Device
Single Wall Spill Bucket
3/20/2025
3/20/2028
Tank
Composite Double Wall Lannon
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
3/20/2025
Tank
Composite Double Wall Lannon
Precision Test (Tank)
Pass
3/27/2020
Tank Number 13
Capacity:
7000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/20/2009
Abandoned Material:
Current Age:
16
Abandoned Date:
Install Date:
5/14/2009
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Composite Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
3/20/2025
3/20/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus
3/20/2025
3/20/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
3/20/2025
3/20/2026
Overfill Prev Device
Overfill Drop Tube Valve
4/8/2024
4/8/2027
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/20/2025
3/20/2028
Leak Detect - Piping
Sump Sensor
3/20/2025
3/20/2026
Spill Contain Device
Single Wall Spill Bucket
3/20/2025
3/20/2028
Tank
Composite Double Wall Lannon
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
3/20/2025
Tank
Composite Double Wall Lannon
Precision Test (Tank)
Pass
3/27/2020
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/15/2025
4/15/2028
Leak Detect - Piping
Sump Sensor
3/20/2025
3/20/2026
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/15/2025
4/15/2028
Leak Detect - Piping
Sump Sensor
3/20/2025
3/20/2026
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/15/2025
4/15/2028
Leak Detect - Piping
Sump Sensor
3/20/2025
3/20/2026
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/20/2025
3/20/2028
Leak Detect - Piping
Sump Sensor
3/20/2025
3/20/2026
MFD
Motorfuel Dispensing Forms
No Forms Found