Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2022790
Status: Active
Facility Name: BP Wash-N-Go
Address: 2S780 IL Route 53 Glen Ellyn, IL 60137
County: Du Page
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001179
Green Tag Issue Date: 5/7/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: FMI Properties, LLC
Owner Address: P.O. Box 3323 Lisle, IL 60532
Owner Status: Current Owner
Purchase Date: 12/17/2010
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 11/25/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038152 FMI Properties, LLC Current Owner 12/17/2010
U0032360 Angel Associates, LP Former Owner 12/15/2009
U0027493 Amoco Oil Company Former Owner 1/1/1985
U0000552 BP Products North America, Inc. Former Owner 1/1/1985
U0035998 Gil, Mark Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261104 (Pending)    Issue Date: 4/23/2026    Expiration Date: 6/22/2026    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Installed but 5/6 and 7/8 no voice

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20210064 Eligible 4/26/2021 4/29/2021 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/1/1985
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: 1/1/1985 Fee Due:
Product Date: 1/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 2/17/2026 2/17/2027
Corrosion Prot - Tank Impressed Current Cathodic Protection 2/17/2026 2/17/2027
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/17/2026 2/17/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/17/2026 2/17/2027
Overfill Prev Device Overfill Drop Tube Valve 2/19/2025 2/19/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/27/2024 2/27/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 10/5/2023
Tank Steel Single Wall Precision Test (Tank) Pass 9/21/2023



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 2/17/2026 2/17/2027
Corrosion Prot - Tank Impressed Current Cathodic Protection 2/17/2026 2/17/2027
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/17/2026 2/17/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/17/2026 2/17/2027
Overfill Prev Device Overfill Drop Tube Valve 2/19/2025 2/19/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/27/2024 2/27/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 4/21/2022
Tank Steel Single Wall Precision Test (Tank) Pass 3/9/2020



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 2/17/2026 2/17/2027
Corrosion Prot - Tank Impressed Current Cathodic Protection 2/17/2026 2/17/2027
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/17/2026 2/17/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/17/2026 2/17/2027
Overfill Prev Device Overfill Drop Tube Valve 2/19/2025 2/19/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/27/2024 2/27/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 4/21/2022
Tank Steel Single Wall Precision Test (Tank) Pass 10/29/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms