Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0040567 |
8301 Bridgeview, LLC |
Current Owner |
4/5/2022 |
| U0037844 |
AZ SPE, LLC |
Former Owner |
3/27/2015 |
| U0001951 |
Bridgeview Bank |
Former Owner |
4/9/2010 |
| U0035286 |
A & D Citgo |
Former Owner |
8/1/2008 |
| U0033807 |
Boudakh, Donna |
Former Owner |
5/16/2006 |
| U0027042 |
TGS New Enterprises Limited, LLC |
Former Owner |
6/17/2002 |
| U0008299 |
Kean Bros, Inc. |
Former Owner |
1/1/1987 |
| U0024145 |
Sandhu Petroleum Corporation Number 2 |
Former Owner |
|
| U0034105 |
K & M Global |
Former Owner |
|
Permits (Unexpired)
Click for permit history
| Permit Number |
Type |
Status |
OSFM Receive Date |
Issue Date |
Expiration Date |
Documents |
| 00300-2026UPG |
Upgrade |
Approved / Amended |
12/17/2025 |
3/18/2026 |
9/18/2026 |
Documents |
| 00174-2026REM |
Removal |
Approved / Amended |
2/15/2026 |
2/17/2026 |
8/18/2026 |
Documents |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 18-0647 |
7/11/2018 |
Removal Log |
00732-2018REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 20240438 |
Eligible |
6/23/2025
|
7/2/2025
|
$5,000
|
Letter
|
Tank Number 1
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
9/28/1987 |
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
28 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
9/28/1987 |
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
28 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
9/28/1987 |
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
24 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 4
| Capacity: |
2000 |
|
Petroleum Use: |
|
| Product: |
Kerosene |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
9/28/1987 |
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
24 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 5
| Capacity: |
2000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
7/11/2018 |
|
OSFM
First Notify Date: |
4/27/1990 |
|
Abandoned Material: |
|
| Current Age: |
30 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1987 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
9/1/2016 |
|
Fee Due: |
$0.00 |
| Product Date: |
9/30/1987 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
European with No Test Req Suction |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 6
| Capacity: |
10000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/27/1990 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1987 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/30/1987 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
6/20/2025 |
6/20/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
6/8/2026 |
6/8/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/4/2026 |
6/4/2029 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
6/4/2026 |
6/4/2029 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
6/4/2026 |
6/4/2029 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
6/4/2026 |
6/4/2029 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
4/10/2024
|
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
3/3/2022
|
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC
|
Precision Test (Piping)
|
Pass
|
6/4/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
6/4/2026
|
Tank Number 7
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/27/1990 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1987 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/30/1987 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/21/2025 |
4/21/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
6/8/2026 |
6/8/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/4/2026 |
6/4/2029 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
6/4/2026 |
6/4/2029 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
6/4/2026 |
6/4/2029 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
6/4/2026 |
6/4/2029 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
3/3/2022
|
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
4/10/2024
|
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC
|
Precision Test (Piping)
|
Pass
|
6/4/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
6/4/2026
|
Tank Number 8
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/27/1990 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1987 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/30/1987 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/21/2025 |
4/21/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
6/8/2026 |
6/8/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/4/2026 |
6/4/2029 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
6/4/2026 |
6/4/2029 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
6/4/2026 |
6/4/2029 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
6/4/2026 |
6/4/2029 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
3/3/2022
|
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
4/10/2024
|
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC
|
Precision Test (Piping)
|
Pass
|
6/4/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
6/4/2026
|
Tank Number 9
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/27/1990 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1987 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/30/1987 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
5/1/2025 |
5/1/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/21/2025 |
4/21/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
6/8/2026 |
6/8/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/4/2026 |
6/4/2029 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
6/4/2026 |
6/4/2029 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
6/4/2026 |
6/4/2029 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
6/4/2026 |
6/4/2029 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
4/10/2024
|
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
3/3/2022
|
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC
|
Precision Test (Piping)
|
Pass
|
6/4/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
6/4/2026
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
| Facility Number |
Name |
City |
Received Date |
Letter |
|
2022723
|
8301 Bridgeview, LLC
|
Bridgeview
|
03/16/2026
|
Letter
Form
|