Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021476
Status: Active
Facility Name: Rockbuild Enterprises, Inc. d/b/a Kedzie Auto Service
Address: 5301 S. Kedzie Chicago, IL 60632
County: Cook
Property Parcel: 19-12-316-041-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA02194
Green Tag Issue Date: 8/27/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Rockbuild Enterprises, Inc.
Owner Address: 3720 Albert Lane Long Grove, IL 60047
Owner Status: Current Owner
Purchase Date: 12/15/2020
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 5/24/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034774 Rockbuild Enterprises, Inc. Current Owner 12/15/2020
U0016367 Wholesale Oil Company Former Owner 1/1/1985
U0028367 Kedzie Auto Service Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
22-0402 5/10/2022 Removal Log 00468-2022REM
22-0409 5/11/2022 Removal Log 00468-2022REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20220402 Eligible 1/20/2023 1/24/2023 $5,000 Letter
20171069 Eligible 1/20/2023 1/24/2023 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/10/2022
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 2/28/2017 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 2/28/2013 2/28/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/5/2016 10/5/2017
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/10/2022
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/5/2003 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 2/28/2013 2/28/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/20/2015 10/20/2016
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/11/2022
OSFM First Notify Date: 4/10/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 33 Abandoned Date: 10/4/2006
Install Date: Red Tag Issue Date:
Last Used Date: 12/20/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/11/2022
OSFM First Notify Date: 4/10/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 33 Abandoned Date: 10/4/2006
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Waste Oil CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 33 Abandoned Date: 10/4/2006
Install Date: Red Tag Issue Date:
Last Used Date: 12/20/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/20/2025 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 5/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2025 8/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 8/21/2025 8/21/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/21/2025 8/21/2026
Overfill Prev Device Overfill Drop Tube Valve 8/21/2025 8/21/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026
Spill Contain Device Single Wall Spill Bucket 4/22/2024 4/22/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/21/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/21/2025



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/20/2025 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 5/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2025 8/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 8/21/2025 8/21/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/21/2025 8/21/2026
Overfill Prev Device Overfill Drop Tube Valve 8/21/2025 8/21/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026
Spill Contain Device Single Wall Spill Bucket 4/22/2024 4/22/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/21/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/21/2025



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/20/2025 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 5/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2025 8/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 8/21/2025 8/21/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/21/2025 8/21/2026
Overfill Prev Device Overfill Drop Tube Valve 8/21/2025 8/21/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026
Spill Contain Device Single Wall Spill Bucket 4/22/2024 4/22/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/21/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/21/2025

Dispenser Information



Name\ID Dispenser 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026



Name\ID Dispenser 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026



Name\ID Dispenser 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026



Name\ID Dispenser 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026

MFD Motorfuel Dispensing Forms

No Forms Found