Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021389
Status: Active
Facility Name: M.P. Sales & Service, Incorporated
Address: 600 Eastern Avenue Bellwood, IL 60104
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00035
Green Tag Issue Date: 5/20/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: M.P. Sales & Service Incorporated
Owner Address: 600 Eastern Avenue Bellwood, IL 60104
Owner Status: Current Owner
Purchase Date: 11/23/2003
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/10/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/20/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0032880 M.P. Sales & Service Incorporated Current Owner 11/23/2003
U0036199 Erumeley, Incorporated Former Owner 4/10/2010
U0005942 Go-Tane Service Stations, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252932 (Pending)    Issue Date: 11/4/2025    Expiration Date: 1/3/2026    View NOV Form

Tanks Violations
5, 6, 7 Annual electronic line leak detector test not completed.
5, 6, 7 Annual leak detection certification not completed (Required annually).
5, 6, 7 Line interstitial sensor functional test not accomplished (Required annually).
5, 6, 7 Tank interstitial sensor functional test not accomplished (Required annually).

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
16-0633 7/21/2016 Removal Log 00640-2016REM
16-0633 7/20/2016 Removal Log 00640-2016REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
03-1650 Eligible 1/5/2004 1/26/2004 $10,000
20160633 Eligible 6/14/2018 6/15/2018 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/21/2016
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 10/8/2015 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/8/2014 1/8/2015
Corrosion Prot - Tank Lining Materials Internal 5/27/2011 5/27/2016
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/15/2015 9/15/2016
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/21/2016
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 1/13/2016 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/8/2014 1/8/2015
Corrosion Prot - Tank Lining Materials Internal 5/27/2011 5/27/2016
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/15/2015 9/15/2016
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/20/2016
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: 1/13/2016 Fee Due: $0.00
Product Date: 1/1/1975

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/8/2014 1/8/2015
Corrosion Prot - Tank Lining Materials Internal 5/27/2011 5/27/2016
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/15/2015 9/15/2016
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/20/2016
OSFM First Notify Date: 5/5/1986 Abandoned Material: Tripolymer Foam
Current Age: 48 Abandoned Date: 3/24/2006
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/6/2017 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/28/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/2/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/7/2024 10/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/7/2024 10/7/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/7/2024 10/7/2025
Overfill Prev Device Overfill Drop Tube Valve 10/7/2024 10/7/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/7/2024 10/7/2025
Spill Contain Device Single Wall Spill Bucket 10/7/2024 10/7/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/7/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 4/11/2023



Tank Number 6

Capacity: 5000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/6/2017 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/28/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/2/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/7/2024 10/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/7/2024 10/7/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/7/2024 10/7/2025
Overfill Prev Device Overfill Drop Tube Valve 10/7/2024 10/7/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/7/2024 10/7/2025
Spill Contain Device Single Wall Spill Bucket 10/7/2024 10/7/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/7/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 4/11/2023



Tank Number 7

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/6/2017 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/28/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/2/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/7/2024 10/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/7/2024 10/7/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/7/2024 10/7/2025
Overfill Prev Device Overfill Drop Tube Valve 10/7/2024 10/7/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/7/2024 10/7/2025
Spill Contain Device Single Wall Spill Bucket 10/7/2024 10/7/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/7/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 4/11/2023



Tank Number 8

Capacity: 2000 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 7/20/2016
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/7/2024 10/7/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/7/2024 10/7/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/7/2024 10/7/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/7/2024 10/7/2025

MFD Motorfuel Dispensing Forms

No Forms Found