Division of Petroleum & Chemical Safety

 
Pay Tank Fees Online Print Detail Page Export to Excel

Facility Details

Facility Number: 2021194
Status: Active
Facility Name: Circle K #6710
Address: 106 Northwest Highway @ Main Street Barrington, IL 60010
County: Lake
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000717
Green Tag Issue Date: 2/20/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: RDK Ventures LLC
Owner Address: 1120 W. Warner Rd. Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 1/7/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/27/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures LLC Current Owner 1/7/2010
U0013839 Shelby Farm Power Former Owner 9/12/1998
U0027449 Equilon Enterprises, LLC Former Owner 9/3/1998
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020260422 (Pending)    Issue Date: 2/23/2026    Expiration Date: 4/24/2026    View NOV Form

Tanks Violations
Facility Fire Extinguishers - Past due for annual testing - Fire extinguishers last passing test was Jan 2024. Currently tagged as defecient.

NOV Number: E0020260423 (Pending)    Issue Date: 2/23/2026    Expiration Date: 4/24/2026    View NOV Form

Tanks Violations
5, 6, 7 Dispensers - hoses cracked, split or worn and require replacement
Facility Emergency Shutoff Switch required - Emergency stop at control station shall be conspicuously marked by a sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters. (Per 41 Ill Admin code 175.210(d)(3))
Facility Missing copy of emergency instructions or emergency procedures plan - Emergency Procedures plan shall be maintained on site for viewing and reference as necessary (See Operator Training Rules 176.645). The emergency plan template is available on the OSFM website.
Facility Operations & Maintenance plan missing required frequencies - Adopt and implement a written operations and maintenance plan, signed by both the owner and either a Class A or Class B Operator designated for the UST facility An Operations & Maintenance template is available at www.sfm.illinois.gov to download and complete O & M template and maintain completed form on site.
5, 6, 7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
5, 6, 7 Tank monitor does not appear to function properly and requires maintenance. - Tank monitor is only printing blank receipts.
5, 6, 7 Verify and test piping sump sensor for positive shutdown - OSFM records indicate sump sensors for Dispensers 1/2, 3/4, 7/8, 9/10 and 11/12 have positive shutdown. Verify and confirm.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-1379 Eligible 6/22/1998 7/14/1998 $10,000
Pay Tank Fees Online

Tank Information

Tank Number Capacity Product Status Regulated Status Red Tag Issued Fee Due Abandon/Removal Date
1 10000 Gasoline Removed Federal $0.00 06/09/1998 - REM
2 10000 Gasoline Removed Federal $0.00 06/09/1998 - REM
3 8000 Gasoline Removed Federal $0.00 06/09/1998 - REM
4 1000 Used Oil Removed Federal $0.00 06/09/1998 - REM
5 12000 Gasoline - Regular Currently in use Federal $0.00
6 12000 Gasoline - Regular Currently in use Federal $0.00
7 10000 Gasoline - Premium Currently in use Federal $0.00

Dispenser Information

Name\ID Status
5/6 Active
1/2 Active
3/4 Active
7/8 Active
9/10 Active
11/12 Active

MFD Motorfuel Dispensing Forms

No Forms Found