Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021060
Status: Active
Facility Name: True North Location 3001
Address: 1201 Chicago Ave. Evanston, IL 60202
County: Cook
Property Parcel: 11-19-200-013-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA03207
Green Tag Issue Date: 12/22/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: 1201 Chicago Ave., Inc.
Owner Address: 1201 Chicago Avenue Evanston, IL 60202
Owner Status: Current Owner
Purchase Date: 11/22/2006
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/27/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034039 1201 Chicago Ave., Inc. Current Owner 11/22/2006
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner
U0027449 Equilon Enterprises, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
15-0596 6/3/2015 Removal Log 00348-2015REM
15-0596 6/2/2015 Removal Log 00348-2015REM
15-0596 6/4/2015 Removal Log 00348-2015REM
91-0258 2/4/1993 Removal Log 7449-92
91-0299 7/22/1991 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
15-0596 Partial Eligible 6/10/2015 6/29/2015 $5,000
20240806 Eligible 12/30/2024 12/30/2024 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/4/2015
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 6/2/2015 Fee Due: $0.00
Product Date: 1/1/1970

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 7/28/2011 7/28/2016
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/7/2014 5/7/2015
Leak Detect - Piping Sump Sensor 5/7/2014 5/7/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/2/2015
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 6/2/2015 Fee Due: $0.00
Product Date: 1/1/1970

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 7/28/2011 7/28/2016
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/7/2014 5/7/2015
Leak Detect - Piping Sump Sensor 5/7/2014 5/7/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/3/2015
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 6/3/2015 Fee Due: $0.00
Product Date: 1/1/1970

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 7/28/2011 7/28/2016
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/7/2014 5/7/2015
Leak Detect - Piping Sump Sensor 5/7/2014 5/7/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/22/1991
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 7/22/1991
OSFM First Notify Date: 2/7/1991 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 2/1/1970 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 6

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/7/2024
OSFM First Notify Date: 12/19/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 9/15/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/15/1991

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Gravity Feed Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/12/2024 6/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/12/2024 6/12/2025
Overfill Prev Device Less than 25 gallon fills Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated 7/12/2024 7/12/2027
Spill Contain Device Field Constructed less than 25 gallon fills Not applicable Not applicable
Tank Fiberglass Brine Filled Double Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Spill Contain Device Field Constructed less than 25 gallon fills Functional Pass 12/17/2021



Tank Number 7

Capacity: 150 Petroleum Use:
Product: Mineral Spirits CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/4/1991
OSFM First Notify Date: 12/19/1991 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1902 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 8

Capacity: 150 Petroleum Use:
Product: Mineral Spirits CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/4/1991
OSFM First Notify Date: 12/19/1991 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1902 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 9

Capacity: 150 Petroleum Use:
Product: Mineral Spirits CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/4/1991
OSFM First Notify Date: 12/19/1991 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1902 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 10

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 7/23/1991
OSFM First Notify Date: 12/19/1991 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1902 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 11

Capacity: 100 Petroleum Use:
Product: Mineral Spirits CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 2/5/1993
OSFM First Notify Date: 2/11/1993 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 1/1/1960 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 12

Capacity: 550 Petroleum Use:
Product: Mineral Spirits CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 2/4/1993
OSFM First Notify Date: 2/11/1993 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 1/1/1960 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 13

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 10/28/2008
OSFM First Notify Date: 11/24/2008 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 14

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/13/2015 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 6/9/2015 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 6/30/2015

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/24/2026 6/24/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/24/2026 6/24/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/24/2026 6/24/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve Not applicable Not applicable
Overfill Prev Device Overfill Drop Tube Valve 11/5/2025 11/5/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 7/12/2024 7/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/12/2024 7/12/2027
Spill Contain Device Double Wall Spill Bucket 7/12/2024 7/12/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/24/2026



Tank Number 15

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/13/2015 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 6/9/2015 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 6/30/2015

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/24/2026 6/24/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/24/2026 6/24/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/24/2026 6/24/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve Not applicable Not applicable
Overfill Prev Device Overfill Drop Tube Valve 11/5/2025 11/5/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 7/12/2024 7/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/12/2024 7/12/2027
Spill Contain Device Double Wall Spill Bucket 7/12/2024 7/12/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/24/2026



Tank Number 16

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 6/4/2015
OSFM First Notify Date: 6/10/2015 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/12/2024 7/12/2027
Leak Detect - Piping Sump Sensor 6/24/2026 6/24/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/12/2024 7/12/2027
Leak Detect - Piping Sump Sensor 6/24/2026 6/24/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/12/2024 7/12/2027
Leak Detect - Piping Sump Sensor 6/24/2026 6/24/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found