Facility Details
Facility Number:
2020577
Status:
Active
Facility Name:
Chase Products Co. (DE)
Address:
2801 Gardner Road Broadview, IL 60153
County:
Cook
Property Parcel:
15-21-420-058-0000
Facility Type:
Industrial / Manufacturing
Owner Type:
Private
Green Tag Decal:
AA00187
Green Tag Issue Date:
4/16/2025
Green Tag Expire Date:
12/31/2027
MFD Type:
N/A
Owner Details
Owner Name:
Chase Products Co. (DE)
Owner Address:
2801 Gardner Road Broadview, IL 60153
Owner Status:
Current Owner
Purchase Date:
1/1/1968
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
5/5/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0002786
Chase Products Co. (DE)
Current Owner
1/1/1968
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
14-0062
6/12/2014
Abandonment Log
00136-2014ABN
14-0062
6/10/2014
Abandonment Log
00136-2014ABN
14-0062
6/9/2014
Abandonment Log
00136-2014ABN
14-0722
6/24/2014
Removal Log
00133-2014REM
14-0722
6/20/2014
Removal Log
00133-2014REM
14-0722
6/23/2014
Removal Log
00133-2014REM
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 6
Capacity:
6000
Petroleum Use:
Product:
Heptane
CERCLA Substance:
Heptane
Status:
Abandoned in place
CAS Code:
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
43
Abandoned Date:
6/9/2014
Install Date:
Red Tag Issue Date:
Last Used Date:
11/1/2011
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Tank
Impressed Current Cathodic Protection
11/24/2010
11/24/2011
Corrosion Prot - Tank
Sacrificial Anode Cathodic Protection
11/24/2010
11/24/2013
Corrosion Prot - Tank
Bladders Internal Tank Bladder
N/A
N/A
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik II
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
6000
Petroleum Use:
Product:
Hazardous Substance
CERCLA Substance:
Butyl Cellosolve
Status:
Abandoned in place
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
46
Abandoned Date:
6/10/2014
Install Date:
Red Tag Issue Date:
Last Used Date:
9/7/2011
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Tank
Impressed Current Cathodic Protection
11/24/2010
11/24/2011
Corrosion Prot - Tank
Sacrificial Anode Cathodic Protection
11/24/2010
11/24/2013
Corrosion Prot - Tank
Bladders Internal Tank Bladder
N/A
N/A
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik II
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
6000
Petroleum Use:
Product:
Methanol
CERCLA Substance:
Methanol
Status:
Abandoned in place
CAS Code:
67-56-1
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
47
Abandoned Date:
6/10/2014
Install Date:
Red Tag Issue Date:
Last Used Date:
1/1/1995
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
6000
Petroleum Use:
Product:
Heptane
CERCLA Substance:
Heptane
Status:
Removed
CAS Code:
Regulated Status:
Non-Regulated
Removed Date:
2/22/1999
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/1/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 10
Capacity:
6000
Petroleum Use:
Product:
Hazardous Substance
CERCLA Substance:
SDA Alcohol
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
2/22/1999
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/1/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 11
Capacity:
18000
Petroleum Use:
Product:
Non Regulated
CERCLA Substance:
Liquid petro gas mixture
Status:
Aboveground
CAS Code:
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Current Age:
29
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 12
Capacity:
18000
Petroleum Use:
Product:
Non Regulated
CERCLA Substance:
Liquid Petroleum Gas
Status:
Aboveground
CAS Code:
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Current Age:
29
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 13
Capacity:
18000
Petroleum Use:
Product:
Non Regulated
CERCLA Substance:
Liquid Petroleum Gas
Status:
Aboveground
CAS Code:
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Current Age:
29
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 14
Capacity:
8300
Petroleum Use:
Product:
Acetone
CERCLA Substance:
Acetone/Toluene blend
Status:
Abandoned in place
CAS Code:
67-64-1
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
31
Abandoned Date:
6/12/2014
Install Date:
Red Tag Issue Date:
Last Used Date:
8/16/2011
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Tank
Impressed Current Cathodic Protection
11/24/2010
11/24/2011
Corrosion Prot - Tank
Sacrificial Anode Cathodic Protection
11/24/2010
11/24/2013
Corrosion Prot - Tank
Bladders Internal Tank Bladder
N/A
N/A
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik II
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 15
Capacity:
8300
Petroleum Use:
Product:
Hazardous Substance
CERCLA Substance:
Naphthenic Solvent
Status:
Removed
CAS Code:
64742-47-8
Regulated Status:
Federal
Removed Date:
6/20/2014
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Current Age:
46
Abandoned Date:
Install Date:
1/1/1968
Red Tag Issue Date:
Last Used Date:
8/19/2011
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Tank
Impressed Current Cathodic Protection
11/24/2010
11/24/2011
Corrosion Prot - Tank
Sacrificial Anode Cathodic Protection
11/24/2010
11/24/2013
Corrosion Prot - Tank
Bladders Internal Tank Bladder
N/A
N/A
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik II
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 16
Capacity:
8300
Petroleum Use:
Product:
Mineral Spirits
CERCLA Substance:
Mineral Spirits
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/23/2014
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Current Age:
46
Abandoned Date:
Install Date:
1/1/1968
Red Tag Issue Date:
Last Used Date:
9/14/2011
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Tank
Impressed Current Cathodic Protection
11/24/2010
11/24/2011
Corrosion Prot - Tank
Sacrificial Anode Cathodic Protection
11/24/2010
11/24/2013
Corrosion Prot - Tank
Bladders Internal Tank Bladder
N/A
N/A
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik II
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 17
Capacity:
8300
Petroleum Use:
Product:
Hazardous Substance
CERCLA Substance:
68-554-99-4
Status:
Removed
CAS Code:
Phenolic Resin
Regulated Status:
Federal
Removed Date:
6/24/2014
OSFM
First Notify Date:
5/5/1986
Abandoned Material:
Current Age:
31
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
9/14/2011
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Tank
Impressed Current Cathodic Protection
11/24/2010
11/24/2011
Corrosion Prot - Tank
Sacrificial Anode Cathodic Protection
11/24/2010
11/24/2013
Corrosion Prot - Tank
Bladders Internal Tank Bladder
N/A
N/A
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik II
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 18
Capacity:
10000
Petroleum Use:
Product:
Acetone
CERCLA Substance:
Acetone
Status:
Currently in use
CAS Code:
67-64-1
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/16/1998
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
10/26/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
12/8/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Other Aboveground Piping
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
2/20/2026
2/20/2027
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
2/20/2026
2/20/2029
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 EVO
3/6/2026
3/6/2027
Overfill Prev Device
Overfill Alarm
3/6/2026
3/6/2029
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Field Constructed
3/6/2026
3/6/2029
Tank
STIP3 Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 19
Capacity:
10000
Petroleum Use:
Product:
LPA-210 Solvent
CERCLA Substance:
LPA-210 Solvent
Status:
Unknown
CAS Code:
64742-47-8
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
12/16/1998
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
10/26/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
12/8/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Other Aboveground Piping
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
4/22/2022
4/22/2023
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
4/22/2022
4/22/2025
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 EVO
6/16/2023
6/16/2024
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
6/16/2023
6/16/2024
Overfill Prev Device
Overfill Alarm
3/8/2021
3/8/2024
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
6/16/2023
6/16/2026
Tank
STIP3 Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 20
Capacity:
10000
Petroleum Use:
None
Product:
Denatured Alcohol
CERCLA Substance:
Denatured Alcohol
Status:
Unknown
CAS Code:
0
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
12/16/1998
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
10/26/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
12/8/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Other Aboveground Piping
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
6/18/2015
6/18/2016
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
6/18/2015
6/18/2018
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik II
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
6/1/2015
6/1/2016
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
Tank
STIP3 Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 21
Capacity:
10000
Petroleum Use:
Product:
Denatured Alcohol
CERCLA Substance:
SDA 40
Status:
Unknown
CAS Code:
64-17-5
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
12/16/1998
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
10/26/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
12/8/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Other Aboveground Piping
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
4/11/2020
4/11/2021
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
10/30/2017
10/30/2020
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Piping
Sump Sensor
5/8/2020
5/8/2021
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 EVO
5/8/2020
5/8/2021
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
5/8/2020
5/8/2021
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
1/6/2020
1/6/2023
Tank
STIP3 Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 22
Capacity:
8300
Petroleum Use:
Product:
Acetone
CERCLA Substance:
Acetone
Status:
Currently in use
CAS Code:
67-64-1
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
9/23/1999
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
8/27/1999
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
10/27/1999
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Other Aboveground Piping
N/A
N/A
Corrosion Prot - Tank
Composite Non-Corrosive
N/A
N/A
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 EVO
3/6/2026
3/6/2027
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
3/6/2026
3/6/2027
Overfill Prev Device
Overfill Alarm
3/6/2026
3/6/2029
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Field Constructed
3/6/2026
3/6/2029
Tank
Composite Double Wall ACT 100
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 23
Capacity:
8300
Petroleum Use:
Product:
Denatured Alcohol
CERCLA Substance:
SDA
Status:
Unknown
CAS Code:
64-17-5
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
9/23/1999
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
8/27/1999
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
10/27/1999
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Other Aboveground Piping
N/A
N/A
Corrosion Prot - Tank
Composite Non-Corrosive
N/A
N/A
Leak Detect - Piping
Aboveground
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 EVO
5/8/2020
5/8/2021
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
5/8/2020
5/8/2021
Overfill Prev Device
Overfill Alarm
1/16/2018
1/16/2021
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
1/6/2020
1/6/2023
Tank
Composite Double Wall ACT 100
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 24
Capacity:
10100
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
Heating Oil
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
State
Removed Date:
OSFM
First Notify Date:
10/12/1999
Abandoned Material:
Inert material mixed with portland cement
Current Age:
64
Abandoned Date:
6/12/2014
Install Date:
1/1/1962
Red Tag Issue Date:
Last Used Date:
12/31/1990
Fee Due:
$0.00
Product Date:
1/1/1962
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found