Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2019822
Status: Active
Facility Name: Noor Mart, Inc.
Address: 4700 S. Michigan Ave. Chicago, IL 60615
County: Cook
Property Parcel: 20-10-101-032-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002221
Green Tag Issue Date: 9/6/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Munazza Management, LLC
Owner Address: 2377 River Hills Lane Bolingbrook, IL 60490
Owner Status: Current Owner
Purchase Date: 8/28/2023
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041784 Munazza Management, LLC Current Owner 8/28/2023
U0003527 Gago Corp. Former Owner 8/25/1986

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020260874 (Pending)    Issue Date: 4/1/2026    Expiration Date: 5/31/2026    View NOV Form

Tanks Violations
1, 2, 3 Document that emergency shut-off (shear valves) are in proper working order
Facility Missing copies of 30 day Walkthrough Inspection Report.
Facility Missing copies of Annual Walkthrough Inspection Report.
Facility Missing copies of current testing certificates for operator training
Facility Missing copy of emergency instructions or emergency procedures plan
Facility Missing copy of written UST facility operation & maintenance plan
Facility Missing list of designated Class A/B & C Operators
2 Overfill prevention equipment inspection(s) not completed (Required every 3 years).
1, 2, 3 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).

NOV Number: E0020260945 (Pending)    Issue Date: 4/7/2026    Expiration Date: 6/6/2026    View NOV Form

Tanks Violations
Facility Submit Notification Form For Ownership Change

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/11/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 9/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/6/2026 5/6/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/6/2026 5/6/2027
Overfill Prev Device Overfill Drop Tube Valve 2/12/2026 2/12/2029
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/12/2026 2/12/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 5/6/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/8/2023



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/11/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 9/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/6/2026 5/6/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/6/2026 5/6/2027
Overfill Prev Device Overfill Drop Tube Valve 2/12/2026 2/12/2029
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/12/2026 2/12/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 5/6/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/8/2023



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/11/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 9/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/6/2026 5/6/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/6/2026 5/6/2027
Overfill Prev Device Overfill Drop Tube Valve 4/6/2026 4/6/2029
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/12/2026 2/12/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 5/6/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/8/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found