Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2019819
Status: Active
Facility Name: Kelly Nissan, Inc.
Address: 4300 W. 95th Street Oak Lawn, IL 60453
County: Cook
Property Parcel:
Facility Type: Auto Dealer
Owner Type: Private
Green Tag Decal: Z000261
Green Tag Issue Date: 8/19/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Fleet

Owner Details

Owner Name: Kelly Nissan, Inc.
Owner Address: 4300 W. 95th Street Oak Lawn, IL 60453
Owner Status: Current Owner
Purchase Date: 9/15/1982
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/2/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0008347 Kelly Nissan, Inc. Current Owner 9/15/1982

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020260871 (Pending)    Issue Date: 4/2/2026    Expiration Date: 6/1/2026    View NOV Form

Tanks Violations
Facility Miscellaneous - PLEASE REMOVE WOOD ENCLOSURE OVER THE GASOLINE DISPENSER

NOV Number: E0020260872 (Pending)    Issue Date: 4/2/2026    Expiration Date: 6/1/2026    View NOV Form

Tanks Violations
Facility A/B operator retraining required as a result of issuance of the Notice of Violation and must be completed within 30 days.
2, 3, 4, 5 Annual leak detection certification not completed (Required annually). - LAST TEST WAS 1-30-2024
2, 3, 4, 5 Required monthly tank leak test records not available.
2, 3, 4, 5 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
2, 3, 4, 5 Tank precision test required.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 23 Abandoned Date: 10/19/2021
Install Date: Red Tag Issue Date:
Last Used Date: 1/5/2019 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/10/2020 9/10/2023
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 5/1/1982 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 4/8/2026 4/8/2027
Overfill Prev Device Overfill Drop Tube Valve 1/22/2024 1/22/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/22/2024 1/22/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/10/2026



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: New Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 5/1/1982 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 4/8/2026 4/8/2027
Overfill Prev Device Overfill Drop Tube Valve 1/30/2024 1/30/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/22/2024 1/22/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/10/2026



Tank Number 4

Capacity: 1000 Petroleum Use: None
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 5/1/1982 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 4/8/2026 4/8/2027
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/22/2024 1/22/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/10/2026



Tank Number 5

Capacity: 550 Petroleum Use:
Product: Transmission Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 5/1/1982 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 4/8/2026 4/8/2027
Overfill Prev Device Overfill Drop Tube Valve 1/22/2024 1/22/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/22/2024 1/22/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/10/2026

Dispenser Information



Name\ID 1 GAS

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 2 GAS

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found