Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2019784
Status: Active
Facility Name: Circle K #6806
Address: 848 Northwest Highway Fox River Grove, IL 60021
County: McHenry
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002724
Green Tag Issue Date: 6/6/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: RDK Ventures, LLC
Owner Address: 1120 W. Warner Rd. Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 1/7/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 1/26/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/20/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures, LLC Current Owner 1/7/2010
U0013849 Shell Oil Products Former Owner 6/10/1998
U0027449 Equilon Enterprises, LLC Former Owner 10/1/1987
U0016134 Weber Fuels Inc Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251658 (Pending)    Issue Date: 7/1/2025    Expiration Date: 8/30/2025    View NOV Form

Tanks Violations
Facility Code complying instruction/warning signs are not properly mounted at each dispenser island - Self-service instructional signs at dispensers are missing or do not meet minimum requirements. Install appropriate signage. DISP 2 HAS NO SIGN, DISP 4, 8, & 10 HAVE PARTIAL SIGNS.

NOV Number: E0020251659 (Pending)    Issue Date: 7/1/2025    Expiration Date: 8/30/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - All emergency shutoff switches shall be tested annually to verify they shut down all STPs or dispensers. Perform test, complete form (form is available at www.sfm.illinois.gov) and maintain 2 years on site with other annual testing documentation.
12, 13, 14 Line interstitial sensors have been raised and rendered inoperational. - Interstitial sensor(s) has/have been raised rendering it/them ineffective. Repair/replace sensor(s) into proper location so that it can function as designed. DISP 6 HAS RAISED SENSOR, DISPENSOR 7/8 SENSOR IS LAYING HORIZONTALLY AT THE BOTTOM OF THE UDC.
12, 13, 14 Miscellaneous - Provide documentation that annual testing of all shear valves has been conducted and passed. Must maintain 2 years of inspection reports.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and 2 years documentation maintained on site.
Facility Missing copy of written UST facility operation & maintenance plan - Adopt and implement a written operations and maintenance plan, signed by both the owner and either a Class A or Class B Operator designated for the UST facility An Operations & Maintenance template is available at www.sfm.illinois.gov to download and complete O & M template and maintain completed form on site.
12 Monthly line interstitial sensor records not available. - Maintain one NORMAL report per LINE, per month, from ATG. Must maintain 24 months’ worth. THIS REFERS TO SMART SENSORS.
12 Monthly line interstitial sensor records not available. - STAND ALONE SENSORS ARE NOT BEING MONITORED MONTHLY. MUST KEEP A LOG FOR EACH DISPENSER WITH DATE INSPECTED, THE NAME OF THE TESTER, AND SENSOR STATUS, IE. "WORKING OR NOT WORKING".
13 Monthly line interstitial sensor records not available. - Maintain one NORMAL report per LINE, per month, from ATG. Must maintain 24 months’ worth. THIS REFERS TO SMART SENSORS.
13 Monthly line interstitial sensor records not available. - STAND ALONE SENSORS ARE NOT BEING MONITORED MONTHLY. MUST KEEP A LOG FOR EACH DISPENSER WITH DATE INSPECTED, THE NAME OF THE TESTER, AND SENSOR STATUS, IE. "WORKING OR NOT WORKING".
14 Monthly line interstitial sensor records not available. - Maintain one NORMAL report per LINE, per month, from ATG. Must maintain 24 months’ worth. THIS REFERS TO SMART SENSORS.
14 Monthly line interstitial sensor records not available. - STAND ALONE SENSORS ARE NOT BEING MONITORED MONTHLY. MUST KEEP A LOG FOR EACH DISPENSER WITH DATE INSPECTED, THE NAME OF THE TESTER, AND SENSOR STATUS, IE. "WORKING OR NOT WORKING".
12, 13, 14 Precision tank test required. - Precision tank test is required on tank(s) if you cannot provide 24 months’ worth of tank “NORMAL” from ATG.
12, 13, 14 Required monthly tank leak test records not available. - Maintain one PASSing report per TANK, per month, from ATG. Must maintain 24 months’ worth. MISSING ALL OF 2024, VERFIED JULY 2023 - DEC 2023, PERSONALLY PUT TOGETHER JAN - JUNE 2025.
12, 13, 14 Verify and test piping sump sensor for positive shutdown - 7/8 SENSOR IS LAYING HORIZONTALLY AT THE BOTTOM OF THE UDC.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
03-0464 Eligible 6/5/2003 7/7/2003 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/26/1987
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1956 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/26/1987
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1956 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/26/1987
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1956 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/26/1987
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1956 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 11500 Petroleum Use:
Product: #2 Fuel Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/26/1987
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1956 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/26/1987
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1956 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/26/1987
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1956 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/27/1987
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/26/1987
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 1500 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 10/26/1987
OSFM First Notify Date: 5/27/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 275 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 10/26/1987
OSFM First Notify Date: 5/27/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 12

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/27/1998 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 10/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/5/2025 8/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 8/5/2025 8/5/2026
Overfill Prev Device Overfill Drop Tube Valve 8/20/2024 8/20/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/2/2025 4/2/2028
Leak Detect - Piping Sump Sensor 8/5/2025 8/5/2026
Spill Contain Device Double Wall Spill Bucket 8/20/2024 8/20/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 8/5/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/5/2025



Tank Number 13

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/27/1998 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 10/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 8/5/2025 8/5/2026
Overfill Prev Device Overfill Drop Tube Valve 8/20/2024 8/20/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/2/2025 4/2/2028
Leak Detect - Piping Non-Discriminating Sump Sensor 12/11/2019 12/11/2020
Leak Detect - Piping Sump Sensor 8/5/2025 8/5/2026
Spill Contain Device Double Wall Spill Bucket 8/20/2024 8/20/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 8/5/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/5/2025



Tank Number 14

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/27/1998 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 10/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/5/2025 8/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 8/5/2025 8/5/2026
Overfill Prev Device Overfill Drop Tube Valve 8/20/2024 8/20/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/2/2025 4/2/2028
Leak Detect - Piping Sump Sensor 8/5/2025 8/5/2026
Spill Contain Device Double Wall Spill Bucket 8/20/2024 8/20/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 8/5/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/5/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/2/2025 4/2/2028
Leak Detect - Piping Stand Alone Sump Sensor 8/5/2025 8/5/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/2/2025 4/2/2028
Leak Detect - Piping Stand Alone Sump Sensor 8/5/2025 8/5/2026



Name\ID 5

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/2/2025 4/2/2028
Leak Detect - Piping Stand Alone Sump Sensor 8/5/2025 8/5/2026



Name\ID 6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/2/2025 4/2/2028
Leak Detect - Piping Stand Alone Sump Sensor 8/5/2025 8/5/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/2/2025 4/2/2028
Leak Detect - Piping Stand Alone Sump Sensor 8/5/2025 8/5/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/2/2025 4/2/2028
Leak Detect - Piping Stand Alone Sump Sensor 8/5/2025 8/5/2026

MFD Motorfuel Dispensing Forms