Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2019769
Status: Active
Facility Name: AAA Cooper Transportation
Address: 4300 W. 72nd Street Chicago, IL 60629
County: Cook
Property Parcel:
Facility Type: Industrial / Manufacturing
Owner Type: Private
Green Tag Decal: Y003540
Green Tag Issue Date: 8/11/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: AAA Cooper Transportation
Owner Address: P O Box 6827 Dothan, AL 36303
Owner Status: Current Owner
Purchase Date: 4/14/1998
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/9/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/11/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0027270 AAA Cooper Transportation Current Owner 4/14/1998
U0025949 American Freightways Corp Former Owner 6/12/1997
U0000713 Ara Smith Transfer Corp Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252033 (Pending)    Issue Date: 8/11/2025    Expiration Date: 10/10/2025    View NOV Form

Tanks Violations
4 Document that emergency shut-off (shear valves) are in proper working order
Facility Missing copies of Annual Walkthrough Inspection Report.
Facility Missing copies of current testing certificates for operator training
Facility Missing copy of emergency instructions or emergency procedures plan
Facility Missing copy of written UST facility operation & maintenance plan
Facility Missing list of designated Class A/B & C Operators
4 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).
4 Triennial testing for qualifying piping containment sump not completed (Required every 3 years).

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/1/1990
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 550 Petroleum Use:
Product: New Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/1/1990
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/1/1990
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/9/1990 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 8/13/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/13/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 10/27/2023 10/27/2026
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/3/2025 7/3/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/3/2025 7/3/2026
Overfill Prev Device Overfill Drop Tube Valve 7/30/2024 7/30/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 9/10/2021 9/10/2024
Leak Detect - Piping Sump Sensor 7/3/2025 7/3/2026
Spill Contain Device Single Wall Spill Bucket 7/30/2024 7/30/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 7/3/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/3/2025

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found