Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2019245
Status: Active
Facility Name: BP
Address: 29849 SE Frontage Road Wilmington, IL 60481
County: Will
Property Parcel: 03-17-15-100-007-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001638
Green Tag Issue Date: 11/20/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Elite Midwest Properties, LLC
Owner Address: 1535 W. Grand Avenue Chicago, IL 60642
Owner Status: Current Owner
Purchase Date: 5/31/2017
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/21/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041350 Elite Midwest Properties, LLC Current Owner 5/31/2017
U0038862 SJK1, Inc. Former Owner 6/1/2017
U0004152 DLM Oil Corporation Former Owner 7/1/1986

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261467 (Referred to Legal)    Issue Date: 6/4/2026    Expiration Date: 8/3/2026    View NOV Form

Tanks Violations
Facility Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - Attendant does not have an unobstrcted view of all dispensers.
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable
Facility Fire Extinguishers - 2 4A:60BC extinguishers not provided, 1 at or near control station and 1 in the dispensing areas - No fire extinguishers available.

NOV Number: E0020261471 (Referred to Legal)    Issue Date: 6/4/2026    Expiration Date: 8/3/2026    View NOV Form

Tanks Violations
Facility Facility Operation and Maintenance Plan not completed or available. - Form available at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Missing copies of 30 day Walkthrough Inspection Report. - Form available at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Missing copies of Annual Walkthrough Inspection Report. - Form available at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Missing list of designated Class A/B & C Operators - Form available at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
5, 6, 7, 8 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - Liquid in all spill buckets.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1991
OSFM First Notify Date: 11/27/1987 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1990 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1991
OSFM First Notify Date: 11/27/1987 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1990 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1991
OSFM First Notify Date: 11/27/1987 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1990 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1991
OSFM First Notify Date: 11/27/1987 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1990 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/27/1987 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 11/27/1987 Red Tag Issue Date: 8/4/2026
Last Used Date: Fee Due: $0.00
Product Date: 11/27/1987

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/28/2026 8/28/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/28/2026 8/28/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve Not applicable Not applicable
Overfill Prev Device Overfill Drop Tube Valve 8/19/2024 8/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 8/19/2024 No passing test found
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 No passing test found
Spill Contain Device Single Wall Spill Bucket 8/19/2024 8/19/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/28/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/19/2024



Tank Number 6

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 11/2/1990 Red Tag Issue Date: 8/4/2026
Last Used Date: Fee Due: $0.00
Product Date: 11/2/1990

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/28/2026 8/28/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/28/2026 8/28/2027
Overfill Prev Device Overfill Drop Tube Valve 8/19/2024 8/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 8/19/2024 No passing test found
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 No passing test found
Spill Contain Device Single Wall Spill Bucket 8/19/2024 8/19/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/28/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/19/2024



Tank Number 7

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 11/2/1990 Red Tag Issue Date: 8/4/2026
Last Used Date: Fee Due: $0.00
Product Date: 11/2/1990

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/28/2026 8/28/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/28/2026 8/28/2027
Overfill Prev Device Overfill Drop Tube Valve 8/19/2024 8/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2027
Spill Contain Device Double Wall Spill Bucket 10/9/2024 10/9/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/28/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/19/2024



Tank Number 8

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 11/2/1990 Red Tag Issue Date: 8/4/2026
Last Used Date: Fee Due: $0.00
Product Date: 11/2/1990

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/28/2026 8/28/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/28/2026 8/28/2027
Overfill Prev Device Overfill Drop Tube Valve 8/19/2024 8/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 8/19/2024 No passing test found
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 No passing test found
Spill Contain Device Double Wall Spill Bucket 10/9/2024 10/9/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/28/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/19/2024

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/28/2026 8/28/2027



Name\ID 10s/11m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/28/2026 8/28/2027



Name\ID 11s/12m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/28/2026 8/28/2027



Name\ID 12s

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/28/2026 8/28/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/28/2026 8/28/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/28/2026 8/28/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/28/2026 8/28/2027



Name\ID 9m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/28/2026 8/28/2027



Name\ID 9s/10m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/28/2026 8/28/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found