Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0041350 |
Elite Midwest Properties, LLC |
Current Owner |
5/31/2017 |
| U0038862 |
SJK1, Inc. |
Former Owner |
6/1/2017 |
| U0004152 |
DLM Oil Corporation |
Former Owner |
7/1/1986 |
Notice of Violations (Current)
NOV Number:
E0020261467
(Referred to Legal)
Issue Date:
6/4/2026
Expiration Date:
8/3/2026
View NOV Form
| Tanks |
Violations |
| Facility |
Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - Attendant does not have an unobstrcted view of all dispensers. |
| Facility |
Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable |
| Facility |
Fire Extinguishers - 2 4A:60BC extinguishers not provided, 1 at or near control station and 1 in the dispensing areas - No fire extinguishers available. |
NOV Number:
E0020261471
(Referred to Legal)
Issue Date:
6/4/2026
Expiration Date:
8/3/2026
View NOV Form
| Tanks |
Violations |
| Facility |
Facility Operation and Maintenance Plan not completed or available. - Form available at:
https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html |
| Facility |
Missing copies of 30 day Walkthrough Inspection Report. - Form available at:
https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html |
| Facility |
Missing copies of Annual Walkthrough Inspection Report. - Form available at:
https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html |
| Facility |
Missing list of designated Class A/B & C Operators - Form available at:
https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html |
| 5, 6, 7, 8 |
Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - Liquid in all spill buckets. |
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
5/1/1991 |
|
OSFM
First Notify Date: |
11/27/1987 |
|
Abandoned Material: |
|
| Current Age: |
35 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/1990 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
5/1/1991 |
|
OSFM
First Notify Date: |
11/27/1987 |
|
Abandoned Material: |
|
| Current Age: |
35 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/1990 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
5/1/1991 |
|
OSFM
First Notify Date: |
11/27/1987 |
|
Abandoned Material: |
|
| Current Age: |
35 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/1990 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 4
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
5/1/1991 |
|
OSFM
First Notify Date: |
11/27/1987 |
|
Abandoned Material: |
|
| Current Age: |
35 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/1990 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 5
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
11/27/1987 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
11/27/1987 |
|
Red Tag Issue Date: |
8/4/2026 |
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/27/1987 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
8/28/2026 |
8/28/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
8/28/2026 |
8/28/2027 |
|
Overfill Prev Device
|
Ball Only Removed Ball Float Vent Valve |
Not applicable |
Not applicable |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/19/2024 |
8/19/2027 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
8/19/2024 |
No passing test found |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
8/19/2024 |
No passing test found |
|
Spill Contain Device
|
Single Wall Spill Bucket |
8/19/2024 |
8/19/2027 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
8/28/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
8/19/2024
|
Tank Number 6
| Capacity: |
12000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/18/1991 |
|
Abandoned Material: |
|
| Current Age: |
35 |
|
Abandoned Date: |
|
| Install Date: |
11/2/1990 |
|
Red Tag Issue Date: |
8/4/2026 |
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/2/1990 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
8/28/2026 |
8/28/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
8/28/2026 |
8/28/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/19/2024 |
8/19/2027 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
8/19/2024 |
No passing test found |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
8/19/2024 |
No passing test found |
|
Spill Contain Device
|
Single Wall Spill Bucket |
8/19/2024 |
8/19/2027 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
8/28/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
8/19/2024
|
Tank Number 7
| Capacity: |
6000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/18/1991 |
|
Abandoned Material: |
|
| Current Age: |
35 |
|
Abandoned Date: |
|
| Install Date: |
11/2/1990 |
|
Red Tag Issue Date: |
8/4/2026 |
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/2/1990 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
8/28/2026 |
8/28/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
8/28/2026 |
8/28/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/19/2024 |
8/19/2027 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
8/19/2024 |
8/19/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
8/19/2024 |
8/19/2027 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
10/9/2024 |
10/9/2027 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
8/28/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
8/19/2024
|
Tank Number 8
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/18/1991 |
|
Abandoned Material: |
|
| Current Age: |
35 |
|
Abandoned Date: |
|
| Install Date: |
11/2/1990 |
|
Red Tag Issue Date: |
8/4/2026 |
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/2/1990 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
8/28/2026 |
8/28/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
8/28/2026 |
8/28/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/19/2024 |
8/19/2027 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
8/19/2024 |
No passing test found |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
8/19/2024 |
No passing test found |
|
Spill Contain Device
|
Double Wall Spill Bucket |
10/9/2024 |
10/9/2027 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
8/28/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
8/19/2024
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found