Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2019036
Status: Active
Facility Name: Mahoney Environmental Solutions, LLC
Address: 2202 Mound Road
Joliet, IL 60436
County: Will
Property Parcel: 3007193000220000
Facility Type: Industrial / Manufacturing
Owner Type: Private
Green Tag Decal: Z002554
Green Tag Issue Date: 11/18/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Mahoney Environmental Solutions, LLC
Owner Address: 712 Essington Rd.
Joliet, IL 60435
Owner Status: Current Owner
Purchase Date: 5/1/2020
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/18/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 11/18/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039874 Mahoney Environmental Solutions, LLC Current Owner 5/1/2020
U0009581 Mahoney Environmental, Inc. Former Owner 1/1/1975

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
95-1409 Eligible 1/5/1996 1/30/1996 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/2/1986 Abandoned Material:
Current Age: 42 Abandoned Date:
Install Date: 1/1/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1983

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 1/9/2023 1/9/2026
Corrosion Prot - Tank Lining Materials Internal 10/28/2020 10/28/2025
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 12/23/2024 12/23/2025
Overfill Prev Device Overfill Drop Tube Valve 1/17/2023 1/17/2026
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/17/2023 1/17/2026
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 10/28/2020



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/2/1986 Abandoned Material:
Current Age: 42 Abandoned Date:
Install Date: 1/1/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1983

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 1/9/2023 1/9/2026
Corrosion Prot - Tank Lining Materials Internal 10/28/2020 10/28/2025
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 12/23/2024 12/23/2025
Overfill Prev Device Overfill Drop Tube Valve 1/17/2023 1/17/2026
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/17/2023 1/17/2026
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 10/28/2020



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/29/1995
OSFM First Notify Date: 4/2/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: 6/28/1995 Fee Due: $0.00
Product Date: 1/1/1975

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/29/1995
OSFM First Notify Date: 4/2/1986 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/28/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A