Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2018651
Status: Active
Facility Name: Maywood Phillips 66
Address: 409 N. 9Th Ave
Maywood, IL 60153
County: Cook
Property Parcel: 15-11-116-007-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002149
Green Tag Issue Date: 11/29/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Shui Chow
Owner Address: 409 North 9th Street
Maywood, IL 60153
Owner Status: Current Owner
Purchase Date: 10/7/1985
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/31/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/29/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0021140 Chow, Shui Current Owner 10/7/1985
U0002936 Chow , Shui Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020241439 (Pending)    Issue Date: 5/23/2024    Expiration Date: 7/22/2024    View NOV Form

Tanks Violation
Facility Financial responsibility must be reported yearly - Financial Responsibility shall be declared annually; The form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
00-1796 9/21/2000 Removal Log 01671-2000REM
930774 5/11/1994 Removal Log
941119 5/20/1994 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-0774 Eligible 3/2/1995 5/1/1995 $15,000
94-1119 Eligible 3/2/1995 5/1/1995 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8300 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/19/1994
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 5/18/1994 Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/19/1994
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 5/18/1994 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8300 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/11/1994
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 5/1/1994 Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/11/1994
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 5/1/1994 Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/19/1994
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 5/18/1994 Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 1500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/6/1993
OSFM First Notify Date: 11/13/1992 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 1/1/1984 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/19/1994
OSFM First Notify Date: 5/26/1994 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 1/1/1979 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 550 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 5/19/1994
OSFM First Notify Date: 5/26/1994 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 1/1/1979 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 550 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 5/19/1994
OSFM First Notify Date: 5/26/1994 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 1/1/1979 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/27/1994 Abandoned Material: Inert material mixed with portland cement
Current Age: 64 Abandoned Date: 6/27/1994
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 1/1/1979 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/6/1994 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 5/12/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/3/2023 7/3/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/3/2023 7/3/2024
Overfill Prev Device Overfill Drop Tube Valve 6/29/2022 6/29/2025
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 8/14/2023 8/14/2026
Leak Detect - Piping Sump Sensor 7/3/2023 7/3/2024
Spill Contain Device Single Wall Spill Bucket 6/29/2022 6/29/2025
Tank Jacketed Steel Double Wall Total Containment N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 6/6/2023
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test Pass 11/21/2023
Tank Jacketed Steel Double Wall Total Containment Precision Test (Tank) Pass 11/21/2023



Tank Number 12

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/6/1994 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 5/12/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/3/2023 7/3/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/3/2023 7/3/2024
Overfill Prev Device Overfill Drop Tube Valve 6/29/2022 6/29/2025
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 6/29/2022 6/29/2025
Leak Detect - Piping Sump Sensor 7/3/2023 7/3/2024
Spill Contain Device Single Wall Spill Bucket 6/29/2022 6/29/2025
Tank Jacketed Steel Double Wall Total Containment N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 6/15/2021
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test Pass 11/21/2023
Tank Jacketed Steel Double Wall Total Containment Precision Test (Tank) Pass 11/21/2023



Tank Number 13

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/6/1994 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 5/12/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/3/2023 7/3/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/3/2023 7/3/2024
Overfill Prev Device Overfill Drop Tube Valve 6/29/2022 6/29/2025
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 6/29/2022 6/29/2025
Leak Detect - Piping Sump Sensor 7/3/2023 7/3/2024
Spill Contain Device Single Wall Spill Bucket 6/29/2022 6/29/2025
Tank Jacketed Steel Double Wall Total Containment N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 6/15/2021
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test Pass 11/21/2023
Tank Jacketed Steel Double Wall Total Containment Precision Test (Tank) Pass 11/21/2023



Tank Number 14

Capacity: 4000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/6/1994 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 5/12/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/3/2023 7/3/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/3/2023 7/3/2024
Overfill Prev Device Overfill Drop Tube Valve 6/29/2022 6/29/2025
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 6/29/2022 6/29/2025
Leak Detect - Piping Non-Discriminating Sump Sensor 6/10/2019 6/10/2020
Leak Detect - Piping Sump Sensor 7/3/2023 7/3/2024
Leak Detect - Piping Non-Discriminating Sump Sensor 7/3/2023 7/3/2024
Spill Contain Device Single Wall Spill Bucket 6/29/2022 6/29/2025
Tank Jacketed Steel Double Wall Total Containment N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 6/15/2021
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test Pass 11/21/2023
Tank Jacketed Steel Double Wall Total Containment Precision Test (Tank) Pass 11/21/2023



Tank Number 15

Capacity: 550 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 9/21/2000
OSFM First Notify Date: 10/2/2000 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID Kerosene

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found