Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2018383
Status: Active
Facility Name: Minuteman
Address: 3346 S. Harlem Ave, Riverside, IL 60546
County: Cook
Property Parcel: 15-36-214-032-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002647
Green Tag Issue Date: 12/29/2022
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Exron Capitol, Inc.
Owner Address: 3340 S. Harlem Ave. Riverside, IL 60546
Owner Status: Current Owner
Purchase Date: 1/1/1974
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 1/7/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/15/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036308 Exron Capitol, Inc. Current Owner 1/1/1974
U0014941 Texor Petroleum Company, Inc. Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251807 (Pending)    Issue Date: 7/15/2025    Expiration Date: 9/13/2025    View NOV Form

Tanks Violations
1, 3, 4, 5, 6 Impressed current system failed test or appears non operational. Must repair. - FAILED TEST ON 5-8-2024

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
22-0263 6/2/2022 Abandonment Log 00347-2022ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
01-1799 Eligible 4/16/2008 5/8/2008 $10,000
12-0410 Eligible 7/3/2013 8/14/2013 $5,000
20220263 Eligible 11/7/2022 11/10/2022 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/15/2024 5/15/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 5/15/2024 5/15/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/8/2025 5/8/2026
Leak Detect - Tank Automatic Tank Gauging 5/8/2025 5/8/2026
Overfill Prev Device Overfill Drop Tube Valve 5/16/2025 5/16/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/8/2025 5/8/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 5/8/2025



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/3/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 41 Abandoned Date: 6/2/2022
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: 8/17/2020 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/19/2021 5/19/2022
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/19/2021 5/19/2022
Leak Detect - Tank Automatic Tank Gauging 5/19/2021 5/19/2022
Overfill Prev Device Overfill Drop Tube Valve 4/24/2019 4/24/2022
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/24/2019 4/24/2022
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 5/19/2021
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/3/2019



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 46 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/15/2024 5/15/2025
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/8/2025 5/8/2026
Leak Detect - Tank Automatic Tank Gauging 5/8/2025 5/8/2026
Overfill Prev Device Overfill Drop Tube Valve 5/8/2025 5/8/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/8/2025 5/8/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 5/8/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/3/2019



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/15/2024 5/15/2025
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/8/2025 5/8/2026
Leak Detect - Tank Automatic Tank Gauging 5/8/2025 5/8/2026
Overfill Prev Device Overfill Drop Tube Valve 5/16/2025 5/16/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/8/2025 5/8/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 5/8/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/3/2019



Tank Number 5

Capacity: 4000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 46 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/15/2024 5/15/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 5/15/2024 5/15/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/8/2025 5/8/2026
Leak Detect - Tank Automatic Tank Gauging 5/8/2025 5/8/2026
Overfill Prev Device Overfill Drop Tube Valve 5/8/2025 5/8/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/8/2025 5/8/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 5/8/2025
Tank Steel Single Wall Precision Test (Tank) Pass 7/3/2019



Tank Number 6

Capacity: 2000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 5/15/2024 5/15/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/8/2025 5/8/2026
Leak Detect - Tank Automatic Tank Gauging 5/8/2025 5/8/2026
Overfill Prev Device Overfill Drop Tube Valve 5/8/2025 5/8/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/8/2025 5/8/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 5/8/2025
Tank Steel Single Wall Precision Test (Tank) Pass 7/3/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 10/ E85

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 10/Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9 kerosene

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found