Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2017678
Status: Active
Facility Name: Marathon
Address: 3301 West Lake Street Melrose Park, IL 60160
County: Cook
Property Parcel: 15-04-309-013-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000055
Green Tag Issue Date: 5/23/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Melrose Park Real Estate, Inc.
Owner Address: 3301 W Lake Street Melrose Park, IL 60160
Owner Status: Current Owner
Purchase Date: 8/15/2024
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/8/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/23/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041473 Melrose Park Real Estate, Inc. Current Owner 8/15/2024
U0034623 L J 1 Corporation Former Owner 12/28/2007
U0009782 Martin Oil Marketing, Ltd. Former Owner 11/1/1995
U0026552 Speedway, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
94-1135 11/6/1995 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
94-1135 Eligible 7/22/1994 8/3/1994 $10,000
94-1135 Eligible 6/6/2012 6/6/2012 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/17/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 25 Abandoned Date: 11/6/1995
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/17/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 25 Abandoned Date: 11/6/1995
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/6/1995
OSFM First Notify Date: 3/17/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 11/6/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use: None
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/22/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 11/7/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/22/2022 11/22/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/22/2022 11/22/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 11/22/2022 11/22/2025
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/3/2024 5/3/2025
Overfill Prev Device Overfill Drop Tube Valve 7/13/2022 7/13/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/28/2022 11/28/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank STIP3 Single Wall Precision Test (Tank) Pass 11/28/2022



Tank Number 5

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/7/1998 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 11/13/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/11/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/22/2022 11/22/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 11/22/2022 11/22/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/3/2024 5/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/3/2024 5/3/2025
Overfill Prev Device Overfill Drop Tube Valve 11/14/2022 11/14/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/28/2022 11/28/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 12/16/2022
Tank STIP3 Single Wall Precision Test (Tank) Pass 12/16/2022



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/7/1998 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 11/13/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/11/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/22/2022 11/22/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 11/22/2022 11/22/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/3/2024 5/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/3/2024 5/3/2025
Overfill Prev Device Overfill Drop Tube Valve 7/13/2022 7/13/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/28/2022 11/28/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/18/2019
Tank STIP3 Single Wall Precision Test (Tank) Pass 11/28/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID K-1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms