Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2017208
Status:
Active
Facility Name:
HP Gas Fuel
Address:
169 E 146th Street Riverdale, IL 60827
County:
Cook
Property Parcel:
29-04-431-047-0000
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
BB00316
Green Tag Issue Date:
4/17/2026
Green Tag Expire Date:
12/31/2028
MFD Type:
Self Service
Owner Details
Owner Name:
146 Indiana, LLC
Owner Address:
169 E 146th Street Riverdale, IL 60827
Owner Status:
Current Owner
Purchase Date:
12/6/2019
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
4/17/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0041793
146 Indiana, LLC
Current Owner
12/6/2019
U0039225
Firoz Vohra and Tanvir Yusuf Vohra
Former Owner
12/7/2015
U0038654
Tanzeela, Inc.
Former Owner
12/7/2015
U0024145
Sandhu Petroleum Corporation Number 2
Former Owner
1/1/1999
U0024099
Rakhra Illinois
Former Owner
1/1/1999
U0036549
Rakhra Illinois E-Z Go Stations Three, Inc.
Former Owner
1/1/1982
U0002119
B Petro Corporation f/k/a Bulk Petroleum Corporation
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
00088-2026UPG
Upgrade
Approved / Issued
1/22/2026
1/22/2026
7/22/2026
Documents
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
95-0273
7/31/1995
Removal Log
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
95-0273
Eligible
1/31/1997
2/26/1997
$10,000
07-1469
Eligible
3/7/2008
3/27/2008
$10,000
09-0605
Eligible
6/26/2009
7/10/2009
$10,000
09-0605
Eligible
6/11/2012
8/3/2012
$10,000
20090605
Eligible
6/22/2018
6/25/2018
$10,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/31/1995
OSFM
First Notify Date:
3/18/1986
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
2/12/1995
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
12000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/31/1995
OSFM
First Notify Date:
3/18/1986
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
2/12/1995
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
8300
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/31/1995
OSFM
First Notify Date:
3/18/1986
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
2/12/1995
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/9/1996
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
2/23/1996
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
2/27/1996
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Isolation Boots Flex Connector
N/A
N/A
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
12/9/2024
12/9/2027
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
11/18/2025
11/18/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350R with CSLD
1/16/2026
1/16/2027
Overfill Prev Device
Overfill Drop Tube Valve
1/16/2026
1/16/2029
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
11/18/2025
11/18/2028
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping
Precision Test (Piping)
Pass
11/18/2025
Tank
Fiberglass Single Wall
Precision Test (Tank)
Pass
8/10/2022
Tank Number 5
Capacity:
8000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/9/1996
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
2/23/1996
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
2/27/1996
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Isolation Boots Flex Connector
N/A
N/A
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
11/18/2025
11/18/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350R with CSLD
11/18/2025
11/18/2026
Overfill Prev Device
Overfill Drop Tube Valve
1/28/2026
1/28/2029
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Double Wall Spill Bucket
1/28/2026
1/28/2029
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping
Precision Test (Piping)
Pass
11/18/2025
Tank
Fiberglass Single Wall
Precision Test (Tank)
Pass
12/2/2024
Tank Number 6
Capacity:
8000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/9/1996
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
2/23/1996
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
2/27/1996
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Isolation Boots Flex Connector
N/A
N/A
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
12/9/2024
12/9/2027
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
11/18/2025
11/18/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350R with CSLD
11/18/2025
11/18/2026
Overfill Prev Device
Overfill Drop Tube Valve
1/28/2026
1/28/2029
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Double Wall Spill Bucket
1/28/2026
1/28/2029
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping
Precision Test (Piping)
Pass
11/18/2025
Tank
Fiberglass Single Wall
Precision Test (Tank)
Pass
8/10/2022
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found