Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2016776
Status: Active
Facility Name: BP
Address: 5149 W. 79th Street Burbank, IL 60459
County: Cook
Property Parcel: 19-33-207-019-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000237
Green Tag Issue Date: 10/16/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: PPRE, LLC
Owner Address: 200 E. Fabyan Parkway Batavia, IL 60510
Owner Status: Current Owner
Purchase Date: 2/29/2016
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 8/12/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/20/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038242 PPRE, LLC Current Owner 2/29/2016
U0038178 Progressive Petroleum, LLC Former Owner 2/16/2016
U0031954 Gas Mart USA, Inc. Former Owner 10/1/2007
U0032983 Chicago Petro Mart Former Owner 7/1/2005
U0031087 Conoco Phillips Former Owner 1/1/2003
U0011868 Phillips 66 Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2018-0039 1/11/2018 Emergency Response

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20180039 Eligible 4/25/2018 5/3/2018 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1988
OSFM First Notify Date: 2/6/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1988
OSFM First Notify Date: 2/6/1986 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1988
OSFM First Notify Date: 2/6/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1988
OSFM First Notify Date: 2/6/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 560 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1988
OSFM First Notify Date: 2/6/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/12/1990 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 7/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/17/2025 6/17/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/17/2025 6/17/2026
Overfill Prev Device Overfill Drop Tube Valve 6/17/2025 6/17/2028
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 11/2/2021 11/2/2024
Spill Contain Device Single Wall Spill Bucket 6/17/2025 6/17/2028
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 3/10/2021
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 6/17/2025
Piping Steel Single Wall Piping Precision Test (Piping) Pass 6/17/2025
Tank Composite Single Wall ACT 100 Precision Test (Tank) Pass 6/26/2024



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/12/1990 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 7/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/17/2025 6/17/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/17/2025 6/17/2026
Overfill Prev Device Overfill Drop Tube Valve 6/17/2025 6/17/2028
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 9/21/2022 9/21/2025
Spill Contain Device Single Wall Spill Bucket 6/17/2025 6/17/2028
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 3/10/2021
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 11/4/2021
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test (Piping) Pass 6/17/2025
Piping Steel Single Wall Piping Precision Test (Piping) Pass 6/17/2025
Tank Composite Single Wall ACT 100 Precision Test (Tank) Pass 6/26/2024



Tank Number 8

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/12/1990 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 7/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/17/2025 6/17/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/17/2025 6/17/2026
Overfill Prev Device Overfill Drop Tube Valve 6/10/2025 6/10/2028
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 11/2/2021 11/2/2024
Spill Contain Device Single Wall Spill Bucket 6/17/2025 6/17/2028
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 3/10/2021
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 6/17/2025
Piping Steel Single Wall Piping Precision Test (Piping) Pass 6/17/2025
Tank Composite Single Wall ACT 100 Precision Test (Tank) Pass 6/26/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found