Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2016676
Status:
Active
Facility Name:
Glenview Arco, Inc.
Address:
825 Milwaukee Ave. Glenview, IL 60025
County:
Cook
Property Parcel:
04-32-401-185-0000
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Z002628
Green Tag Issue Date:
12/17/2024
Green Tag Expiration Date:
12/31/2026
Owner Details
Owner Name:
Chicago Title Land Trust Company, Trust 10-2293
Owner Address:
825 Milwaukee Ave. Glenview, IL 60025
Owner Status:
Current Owner
Purchase Date:
5/23/2024
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
9/11/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
12/17/2024
12/31/2026
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0041377
Chicago Title Land Trust Company, Trust 10-2293
Current Owner
5/23/2024
U0039288
Aalia, LLC
Former Owner
7/19/2018
U0037218
Glenmill Petroleum, Inc.
Former Owner
9/1/2012
U0008282
Kathes Car Wash Glenview, Inc.
Former Owner
8/1/1995
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
92-3382
9/22/1993
Lining Log
95-0214
1/30/1995
Removal Log
95-0214
1/31/1995
Removal Log
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
92-3382
Eligible
11/30/1993
12/13/1993
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/30/1995
OSFM
First Notify Date:
4/16/1986
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
1/1/1960
Red Tag Issue Date:
Last Used Date:
1/30/1995
Fee Due:
$0.00
Product Date:
1/1/1960
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/30/1995
OSFM
First Notify Date:
4/16/1986
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
1/1/1960
Red Tag Issue Date:
Last Used Date:
11/28/1992
Fee Due:
$0.00
Product Date:
1/1/1960
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/30/1995
OSFM
First Notify Date:
4/16/1986
Abandoned Material:
Current Age:
25
Abandoned Date:
Install Date:
1/1/1970
Red Tag Issue Date:
Last Used Date:
1/30/1995
Fee Due:
$0.00
Product Date:
1/1/1970
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
1000
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/22/1993
OSFM
First Notify Date:
4/16/1986
Abandoned Material:
Current Age:
33
Abandoned Date:
Install Date:
1/1/1960
Red Tag Issue Date:
Last Used Date:
9/17/1993
Fee Due:
$0.00
Product Date:
1/1/1960
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
275
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
Heating Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
1/31/1995
OSFM
First Notify Date:
10/1/1993
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
1/1/1960
Red Tag Issue Date:
Last Used Date:
1/1/1970
Fee Due:
Product Date:
1/1/1960
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
275
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
Heating Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
1/31/1995
OSFM
First Notify Date:
2/14/1995
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
1/1/1960
Red Tag Issue Date:
Last Used Date:
1/1/1970
Fee Due:
Product Date:
1/1/1960
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/18/1996
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
8/30/1995
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/30/1995
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
12/12/2024
12/12/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
12/12/2024
12/12/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
12/12/2024
12/12/2025
Overfill Prev Device
Overfill Drop Tube Valve
12/13/2024
12/13/2027
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
12/13/2024
12/13/2027
Leak Detect - Piping
Sump Sensor
12/12/2024
12/12/2025
Spill Contain Device
Single Wall Spill Bucket
12/13/2024
12/13/2027
Tank
Fiberglass Double Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
12/12/2024
Tank Number 8
Capacity:
12000
Petroleum Use:
None
Product:
E85
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/18/1996
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
8/30/1995
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/30/1995
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
1/8/2025
1/8/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
1/8/2025
1/8/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
1/8/2025
1/8/2026
Overfill Prev Device
Overfill Drop Tube Valve
1/8/2025
1/8/2028
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
12/13/2024
12/13/2027
Leak Detect - Piping
Sump Sensor
12/12/2024
12/12/2025
Leak Detect - Piping
Sump Sensor with positive shutdown
1/8/2025
1/8/2026
Spill Contain Device
Single Wall Spill Bucket
12/13/2024
12/13/2027
Tank
Fiberglass Double Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
1/8/2025
Tank Number 9
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/18/1996
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
8/30/1995
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/30/1995
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
12/12/2024
12/12/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
12/12/2024
12/12/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
12/12/2024
12/12/2025
Overfill Prev Device
Overfill Drop Tube Valve
12/13/2024
12/13/2027
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
12/13/2024
12/13/2027
Leak Detect - Piping
Sump Sensor
12/12/2024
12/12/2025
Spill Contain Device
Single Wall Spill Bucket
12/13/2024
12/13/2027
Tank
Fiberglass Double Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
12/12/2024
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
12/13/2024
12/13/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
1/8/2025
1/8/2026
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
12/13/2024
12/13/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
1/8/2025
1/8/2026
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
12/13/2024
12/13/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
1/8/2025
1/8/2026
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
12/13/2024
12/13/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
1/8/2025
1/8/2026
MFD
Motorfuel Dispensing Forms
No Forms Found