Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2016452
Status: Active
Facility Name: 7700 Kedzie Gas Corp.
Address: 7700 S. Kedzie Chicago, IL 60652
County: Cook
Property Parcel: 19-26-413-047-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA02341
Green Tag Issue Date: 5/7/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Norman Junejo
Owner Address: 7700 S. Kedzie Chicago, IL 60652
Owner Status: Current Owner
Purchase Date: 12/20/2014
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/18/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038493 Junejo, Norman Current Owner 12/20/2014
U0036170 7700 Kedzie Gas Corp. Former Owner 6/1/2011
U0032814 Eintelligence USA Corporation Former Owner 9/14/2004
U0013849 Shell Oil Products Former Owner 6/8/1988
U0000651 B.A.P.A., LLC & PT, LLC Former Owner 12/31/1967
U0031135 Khater, Farid Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261344 (Pending)    Issue Date: 5/20/2026    Expiration Date: 7/19/2026   

Tanks Violations
6, 7 Tank interstitial sensors in alarm or failed test, must repair or replace.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/2/1988
OSFM First Notify Date: 1/6/1986 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 8/1/1988 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/2/1988
OSFM First Notify Date: 1/6/1986 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 8/1/1988 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/2/1988
OSFM First Notify Date: 1/6/1986 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 8/1/1988 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 2000 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1988
OSFM First Notify Date: 10/26/1993 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1902 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 2000 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1988
OSFM First Notify Date: 10/26/1993 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1902 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/19/2003 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 10/22/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/22/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/15/2026 4/15/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 4/15/2026 4/15/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/21/2026 5/21/2027
Overfill Prev Device Overfill Drop Tube Valve 4/15/2026 4/15/2029
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/15/2026 4/15/2029
Leak Detect - Piping Sump Sensor 4/15/2026 4/15/2027
Spill Contain Device Double Wall Spill Bucket 4/15/2026 4/15/2029
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 4/15/2026
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 8/16/2021



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/19/2003 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 10/22/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/22/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/15/2026 4/15/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 4/15/2026 4/15/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/21/2026 5/21/2027
Overfill Prev Device Overfill Drop Tube Valve 4/15/2026 4/15/2029
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/15/2026 4/15/2029
Leak Detect - Piping Sump Sensor 4/15/2026 4/15/2027
Spill Contain Device Double Wall Spill Bucket 4/15/2026 4/15/2029
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 4/15/2026
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 8/16/2021

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms