Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2016100
Status: Active
Facility Name: 5200 Addison Gas, Inc.
Address: 5200 W. Addison Street Chicago, IL 60641
County: Cook
Property Parcel: 13-21-131-027-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA02307
Green Tag Issue Date: 3/31/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: 5200 Addison Property, Inc.
Owner Address: 5200 W. Addison Street Chicago, IL 60641
Owner Status: Current Owner
Purchase Date: 5/20/2023
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/19/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040953 5200 Addison Property, Inc. Current Owner 5/20/2023
U0039155 Addison Oil Co., Inc. Former Owner 11/15/2017
U0015322 Twist Service, Inc. Former Owner 11/15/2017

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20190220 Eligible 6/21/2019 6/25/2019 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 5/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/7/2025 8/7/2026
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/7/2025 8/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root EMC with CSLD 8/7/2025 8/7/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2023 2/21/2026
Piping Steel Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 12/19/2022 12/19/2025
Leak Detect - Piping Sump Sensor 12/19/2022 12/19/2025
Spill Contain Device Single Wall Spill Bucket 2/21/2023 2/21/2026
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 5/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/7/2025 8/7/2026
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Other Non-vented check valve Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root EMC with CSLD 8/7/2025 8/7/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2023 2/21/2026
Piping Steel Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 2/21/2023 2/21/2026
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 5/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/7/2025 8/7/2026
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/7/2025 8/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root EMC with CSLD 8/7/2025 8/7/2026
Overfill Prev Device Overfill Drop Tube Valve 12/19/2022 12/19/2025
Piping Steel Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 12/19/2022 12/19/2025
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found