Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Section 175.410 Submersible, Under-dispenser, Transition and Other Containment Sumps
a) All containment sumps must consist of a factory manufactured containment that is liquid-tight on its sides, bottom and at any penetrations and is compatible with the substance conveyed by the piping. Such containment shall also have a factory manufactured protective cover and supporting components that are properly maintained. If the protective cover or its supporting components are cracked, deteriorated, or missing, the cover and supporting components that are defective shall be replaced. |
| 3, 5 |
Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. |
| 3, 5 |
Tank monitor does not appear to function properly and requires maintenance. - ATG in alarm; repair/replace as necessary to secure alarm. Both tanks show loww product and fail 0.2. |
| 3 |
Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - STP sump(s) contain(s) liquid, creating alarm on ATG. Remove liquid and repair containment to prevent further liquid ingress. Repair/replace sensor(s) as necessary to clear alarm. ALSO PERMIT TO REMOVE CATHODIC PROTECTION AND MAINTAIN SENSORS. |
| 3 |
Water in dispenser containment with interstitial sensors - Remove water and repair containments to prevent water ingress - UDC sump 3/4 contains liquid, creating alarm on ATG. Remove liquid and repair containment to prevent further liquid ingress. Repair/replace sensor(s) as necessary to clear alarm. ALSO PERMIT TO REMOVE CATHODIC PROTECTION AND MAINTAIN SENSORS. |