Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2015787
Status: Active
Facility Name: AASJM, Inc.
Address: 5400 W. Diversey Ave. Chicago, IL 60639
County: Cook
Property Parcel: 13-28-127-040-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002402
Green Tag Issue Date: 6/7/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: AASJM, Inc.
Owner Address: 5400 W. Diversey Ave. Chicago, IL 60639
Owner Status: Current Owner
Purchase Date: 11/1/2017
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/5/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/7/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039082 AASJM, Inc. Current Owner 11/1/2017
U0006369 Abdul Karim Hamidani Former Owner 6/1/1984

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
22-0571 7/7/2022 Removal Log 00690-2022REM
22-0571 7/6/2022 Removal Log 00690-2022REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20220571 Eligible 8/9/2022 8/11/2022 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/7/2022
OSFM First Notify Date: 4/21/1986 Abandoned Material:
Current Age: 51 Abandoned Date:
Install Date: 4/21/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/18/2019 4/18/2022
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 11/13/2019 11/13/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/2/2022 2/2/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 2/2/2022 2/2/2023
Overfill Prev Device Overfill Drop Tube Valve 2/2/2022 2/2/2025
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/2/2022 2/2/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 2/2/2022
Tank Steel Single Wall Precision Test (Tank) Pass 11/14/2019



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/6/2022
OSFM First Notify Date: 4/21/1986 Abandoned Material:
Current Age: 51 Abandoned Date:
Install Date: 4/21/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/18/2019 4/18/2022
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 11/13/2019 11/13/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/2/2022 2/2/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 2/2/2022 2/2/2023
Overfill Prev Device Overfill Drop Tube Valve 2/2/2022 2/2/2025
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/2/2022 2/2/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 2/2/2022
Tank Steel Single Wall Precision Test (Tank) Pass 11/14/2019



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/6/2022
OSFM First Notify Date: 4/21/1986 Abandoned Material:
Current Age: 42 Abandoned Date:
Install Date: 4/21/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/18/2019 4/18/2022
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 11/13/2019 11/13/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/2/2022 2/2/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 2/2/2022 2/2/2023
Overfill Prev Device Overfill Drop Tube Valve 2/2/2022 2/2/2025
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/2/2022 2/2/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 2/2/2022
Tank Steel Single Wall Precision Test (Tank) Pass 11/14/2019



Tank Number 4

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 7/6/2022
OSFM First Notify Date: 4/21/1986 Abandoned Material:
Current Age: Abandoned Date: 4/21/1986
Install Date: Red Tag Issue Date:
Last Used Date: 11/20/1997 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/28/2000
OSFM First Notify Date: 4/21/1986 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 16000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/26/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/19/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/21/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/17/2024 9/17/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/17/2024 9/17/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/17/2024 9/17/2025
Overfill Prev Device Overfill Drop Tube Valve 9/27/2022 9/27/2025
Piping Flexible Double Wall NUPI Smartflex N/A N/A
Piping Single Wall STP/Tanktop Sump 9/23/2022 9/23/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/17/2024 9/17/2025
Spill Contain Device Single Wall Spill Bucket 9/23/2022 9/23/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 9/17/2024
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 9/21/2022



Tank Number 7

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/26/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/19/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/21/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/17/2024 9/17/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/17/2024 9/17/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/17/2024 9/17/2025
Overfill Prev Device Overfill Drop Tube Valve 9/27/2022 9/27/2025
Piping Flexible Double Wall NUPI Smartflex N/A N/A
Piping Single Wall STP/Tanktop Sump 9/23/2022 9/23/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/17/2024 9/17/2025
Spill Contain Device Single Wall Spill Bucket 9/23/2022 9/23/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 9/14/2023
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 9/21/2022



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/26/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/19/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/21/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/17/2024 9/17/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/17/2024 9/17/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/17/2024 9/17/2025
Overfill Prev Device Overfill Drop Tube Valve 9/23/2022 9/23/2025
Piping Flexible Double Wall NUPI Smartflex N/A N/A
Piping Single Wall STP/Tanktop Sump 9/23/2022 9/23/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/17/2024 9/17/2025
Spill Contain Device Single Wall Spill Bucket 9/23/2022 9/23/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 9/17/2024
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 9/21/2022



Tank Number 9

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/26/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/19/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/21/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/17/2024 9/17/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/17/2024 9/17/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/17/2024 9/17/2025
Overfill Prev Device Overfill Drop Tube Valve 9/23/2022 9/23/2025
Piping Flexible Double Wall NUPI Smartflex N/A N/A
Piping Single Wall STP/Tanktop Sump 9/23/2022 9/23/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/17/2024 9/17/2025
Spill Contain Device Single Wall Spill Bucket 9/23/2022 9/23/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 9/17/2024
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 9/21/2022



Tank Number 10

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 7/7/2022
OSFM First Notify Date: 8/2/2022 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/20/1971 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 7/7/2022
OSFM First Notify Date: 8/2/2022 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/20/1971 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump NUPI HDPE 9/23/2022 9/23/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/17/2024 9/17/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump NUPI HDPE 9/23/2022 9/23/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/17/2024 9/17/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump NUPI HDPE 9/23/2022 9/23/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/17/2024 9/17/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2015787 AASJM, Inc. Chicago 09/26/2022 Letter Form