Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2015385
Status: Active
Facility Name: Metro Fuel
Address: 603 West Lake Street Addison, IL 60101
County: Du Page
Property Parcel: 03-20-407-056
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01791
Green Tag Issue Date: 2/27/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Bargeway Plaza, LLC
Owner Address: 1398 Lilac Lane Addison, IL 60101
Owner Status: Current Owner
Purchase Date: 5/1/2002
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/26/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/27/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030953 Bargeway Plaza, LLC Current Owner 5/1/2002
U0003767 Bargeway Oil Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
06-0032 1/11/2006 Removal Log 01397-2005REM
06-0032 1/30/2006 Removal Log 00115-2006REM
17-0606 7/12/2017 Removal Log 00800-2017REM
17-0606 7/11/2017 Removal Log 00800-2017REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/12/2017
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 4/9/1978 Red Tag Issue Date:
Last Used Date: 2/23/2016 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/13/2014 11/13/2015
Corrosion Prot - Tank Lining Materials Internal 12/3/2014 12/3/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/7/2014 11/7/2015
Leak Detect - Piping Sump Sensor 11/6/2014 11/6/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/11/2006
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/1/1988
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/11/2017
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 6/9/1978 Red Tag Issue Date:
Last Used Date: 2/23/2016 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/13/2014 11/13/2015
Corrosion Prot - Tank Lining Materials Internal 12/3/2014 12/3/2019
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Piping Sump Sensor 11/6/2014 11/6/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/11/2006
OSFM First Notify Date: 10/25/2002 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 6/28/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 8000 Petroleum Use: None
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/23/2006 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 1/11/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/11/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/9/2024 9/9/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/9/2024 9/9/2025
Overfill Prev Device Overfill Drop Tube Valve 3/30/2022 3/30/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 3/30/2022 3/30/2025
Leak Detect - Piping Non-Discriminating Sump Sensor 4/4/2019 4/4/2020
Leak Detect - Piping Sump Sensor 9/9/2024 9/9/2025
Spill Contain Device Double Wall Spill Bucket 1/8/2025 1/8/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 9/9/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 1/8/2025



Tank Number 7

Capacity: 500 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 1/30/2006
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/30/2022 3/30/2025
Leak Detect - Piping Sump Sensor 9/9/2024 9/9/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/30/2022 3/30/2025
Leak Detect - Piping Sump Sensor 9/9/2024 9/9/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/30/2022 3/30/2025
Leak Detect - Piping Sump Sensor 9/9/2024 9/9/2025

MFD Motorfuel Dispensing Forms

No Forms Found