Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2015080
Status: Active
Facility Name: Ganesh Foodmart Inc.
Address: 1725 Larkin Avenue Elgin, IL 60123
County: Kane
Property Parcel: 06-15-351-068
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001440
Green Tag Issue Date: 5/9/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Shiv Shakti Realty LLC
Owner Address: 1846 Marbella Drive Elgin, IL 60124
Owner Status: Current Owner
Purchase Date: 12/4/2025
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/22/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041823 Shiv Shakti Realty LLC Current Owner 12/4/2025
U0034283 R & K Petroelum Inc Former Owner 8/26/2011
U0015140 Tr 935 Elgin Natl Bank Former Owner 12/31/1967
U0021437 Boncosky Oil Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261326 (Pending)    Issue Date: 5/19/2026    Expiration Date: 7/18/2026    View NOV Form

Tanks Violations
1, 3 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Section 175.410 Submersible, Under-dispenser, Transition and Other Containment Sumps a) All containment sumps must consist of a factory manufactured containment that is liquid-tight on its sides, bottom and at any penetrations and is compatible with the substance conveyed by the piping. Such containment shall also have a factory manufactured protective cover and supporting components that are properly maintained. If the protective cover or its supporting components are cracked, deteriorated, or missing, the cover and supporting components that are defective shall be replaced. SPECIFICALLY THE STP HANDLES FOR EAST PREM TANK AND THE DIESEL.
Facility Facility Operation and Maintenance Plan not completed or available. - Adopt and implement a written operations and maintenance plan, signed by both the owner and either a Class A or Class B Operator designated for the UST facility An Operations & Maintenance template is available at www.sfm.illinois.gov to download and complete O & M template and maintain completed form on site. UPDATE FORM. LEFT FORM WITH RAJ PATEL
Facility Financial responsibility must be reported yearly - Financial Responsibility shall be declared annually, and must be maintained until the tanks are removed or properly abandoned in place by a licensed UST decommissioning contractor. The form can be found at: https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility.
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and 2 years of documentation maintained on site. 30-Day Walkthrough Inspection form available at www.sfm.illinois.gov. The form must be filled out by an A/B Operator, you must, initial each box that applies, date the form each month to ensure it is being done every 30 days, and the A/B operator must print and sign their name at the bottom. If more than one A/B operator fills out the form, then each must print and sign name at the bottom. LEFT FORM WITH RAJ PATEL.
Facility Missing copy of emergency instructions or emergency procedures plan - Emergency Procedures plan shall be maintained on site for viewing and reference as necessary (See Operator Training Rules 176.645). The emergency plan template is available on the OSFM website. UPDATE FORM. LEFT FORM WITH RAJ PATEL.
Facility Missing list of designated Class A/B & C Operators - A comprehensive list of Class A / B / C Operator(s) shall be maintained on site and must be current. LEFT FORM WITH RAJ PATEL.
1, 2, 3, 4 Required monthly tank leak test records not available.
1, 2, 3, 4 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
Facility Submit Notification Form For Ownership Address Change - Per 41 Ill. Adm. Code 176.440(g), a change in ownership information must be reported on an electronic Notification for Underground Storage Tank form, within 30 days of the change. The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm .
1, 2, 3, 4 Tank monitor does not appear to function properly and requires maintenance. - Indicator Green light on panel of Veeder-Root ATG is not functional. Replace as necessary to provide proper operation.

NOV Number: E0020261327 (Pending)    Issue Date: 5/19/2026    Expiration Date: 7/18/2026    View NOV Form

Tanks Violations
Facility Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - Section 175.210g; All dispensing units shall be readily visible from the control station without assistive devices. If view is permanently obstructed, or the dispenser is located so that activity is not readily visible, closed-circuit cameras that provide a view of each side of the dispensing unit and project an image on a screen at least 6 inches in diagonal located at the control station may be used. You may also elect to install an emergency stop switch at least 20 feet but no more than 50 feet from any dispenser with a permanently obstructed view.
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
92-2846 10/20/1994 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
87-1101 Eligible 10/10/1995 11/8/1995 $50,000
87-1107 Eligible 11/17/2008 12/5/2008 $50,000
87-1107 Eligible 11/20/2014 1/13/2015 $50,000
92-2846 Eligible 2/11/2015 3/24/2015 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 54 Abandoned Date:
Install Date: 6/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/22/2025 5/22/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/8/2025 9/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/8/2025 9/8/2026
Overfill Prev Device Overfill Drop Tube Valve 8/30/2024 8/30/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/30/2024 8/30/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/8/2025



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 9/1/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/22/2025 5/22/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/8/2025 9/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/8/2025 9/8/2026
Overfill Prev Device Overfill Drop Tube Valve 8/30/2024 8/30/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/30/2024 8/30/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/8/2025



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 54 Abandoned Date:
Install Date: 6/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/22/2025 5/22/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/8/2025 9/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/8/2025 9/8/2026
Overfill Prev Device Overfill Drop Tube Valve 10/29/2024 10/29/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/30/2024 8/30/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/8/2025



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 54 Abandoned Date:
Install Date: 6/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/22/2025 5/22/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/8/2025 9/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/8/2025 9/8/2026
Overfill Prev Device Overfill Drop Tube Valve 10/29/2024 10/29/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/30/2024 8/30/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/8/2025



Tank Number 5

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 10/20/1994
OSFM First Notify Date: 7/1/1992 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 6/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/20/1994
OSFM First Notify Date: 7/1/1992 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 6/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found