Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2013831
Status: Active
Facility Name: Elgin AP d/b/a Marathon
Address: 789 Summit St. Elgin, IL 60120
County: Kane
Property Parcel: 06-07-302-048-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01241
Green Tag Issue Date: 5/29/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Ahmad Zahdan
Owner Address: 12345 S. Keeler Ave. Alsip, IL 60803
Owner Status: Current Owner
Purchase Date: 11/2/2015
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/13/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/29/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0032207 Zahdan, Ahmad Current Owner 11/2/2015
U0031960 Pavan, Inc. Former Owner 11/4/2003
U0023990 Lose Dick Former Owner 6/7/1990
U0009663 Marathon Oil Company Former Owner 12/31/1967
U0037861 Tara Petroleum, LLC Former Owner
U0030089 Singh, Harvhajan Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252100 (Pending)    Issue Date: 8/14/2025    Expiration Date: 10/13/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - All emergency shutoff switches shall be tested annually to verify they shut down all STPs or dispensers. Perform test, complete form (form is available at www.sfm.illinois.gov) and maintain 2 years on site with other annual testing documentation.
1, 2, 3 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (interstitial sensors/ATG) not completed. Testing shall be completed and submitted to OSFM.
1, 2, 3 Annual line precision and mechanical line leak detector functional test not completed. - Annual third-party precision line and leak detector test is required.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and 2 years documentation maintained on site.
1, 2, 3 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Provide documentation that annual testing of all shear valves has been conducted and passed. Must maintain 2 years of inspection reports.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use: None
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 52 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: 12/1/2020 Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/5/2024 8/5/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/18/2025 8/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/18/2025 8/18/2026
Overfill Prev Device Overfill Drop Tube Valve 8/18/2025 8/18/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 8/18/2025 8/18/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 8/18/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/19/2021



Tank Number 2

Capacity: 8000 Petroleum Use: None
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 52 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: 12/1/2020 Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/18/2024 7/18/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/18/2025 8/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/18/2025 8/18/2026
Overfill Prev Device Overfill Drop Tube Valve 8/18/2025 8/18/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 8/18/2025 8/18/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 8/18/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/19/2021



Tank Number 3

Capacity: 8000 Petroleum Use: None
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 52 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: 12/1/2020 Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/18/2024 7/18/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/18/2025 8/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/18/2025 8/18/2026
Overfill Prev Device Overfill Drop Tube Valve 8/18/2025 8/18/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 8/18/2025 8/18/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 8/18/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/19/2021



Tank Number 4

Capacity: 550 Petroleum Use: None
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/19/1998
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms