Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2012799
Status: Active
Facility Name: Mariano's
Address: 105 Northwest Highway Crystal Lake, IL 60014
County: McHenry
Property Parcel:
Facility Type: Unattended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001419
Green Tag Issue Date: 4/15/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Unattended Self Service

Owner Details

Owner Name: Roundy's Supermarket, Inc. A division of the Kroger Co.
Owner Address: 875 E. Wisconsin Ave. Milwaukee, WI 53202
Owner Status: Current Owner
Purchase Date: 1/12/2018
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/13/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038806 Roundy's Supermarket, Inc. A division of the Kroger Co. Current Owner 1/12/2018
U0010559 Montgomery Ward & Co Inc Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261695 (Pending)    Issue Date: 7/1/2026    Expiration Date: 8/30/2026    View NOV Form

Tanks Violations
Facility Annual Fire Detection Test has not been performed - Annual fire detection system test shall be performed. Paperwork showing date of passing test shall be maintained on site with other annual testing documentation.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 540 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/1993
OSFM First Notify Date: 1/6/1986 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/1/1993 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2018 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 1/12/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/5/2018

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/4/2025 11/4/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/4/2025 11/4/2026
Manway At Grade Accessible Manway Accessible at Grade Not applicable Not applicable
Overfill Prev Device Overfill Alarm 12/6/2023 12/6/2026
Overfill Prev Device Overfill Drop Tube Valve 12/6/2023 12/6/2026
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 12/6/2023 12/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 12/6/2023 12/6/2026
Spill Contain Device Double Wall Spill Bucket 12/6/2023 12/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 1/3/2023



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2018 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 1/12/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/5/2018

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/4/2025 11/4/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/4/2025 11/4/2026
Manway At Grade Accessible Manway Accessible at Grade Not applicable Not applicable
Overfill Prev Device Overfill Alarm 12/6/2023 12/6/2026
Overfill Prev Device Overfill Drop Tube Valve 12/6/2023 12/6/2026
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 12/6/2023 12/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 12/6/2023 12/6/2026
Spill Contain Device Double Wall Spill Bucket 12/6/2023 12/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 1/3/2023



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2018 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 1/12/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/5/2018

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/4/2025 11/4/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/4/2025 11/4/2026
Manway At Grade Accessible Manway Accessible at Grade Not applicable Not applicable
Overfill Prev Device Overfill Alarm 12/6/2023 12/6/2026
Overfill Prev Device Overfill Drop Tube Valve 12/6/2023 12/6/2026
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 12/6/2023 12/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 12/6/2023 12/6/2026
Spill Contain Device Double Wall Spill Bucket 12/6/2023 12/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 1/3/2023

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/6/2023 12/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 11/4/2025 11/4/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/6/2023 12/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 11/4/2025 11/4/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/6/2023 12/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 11/4/2025 11/4/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/6/2023 12/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 11/4/2025 11/4/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/6/2023 12/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 11/4/2025 11/4/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2012799 Mariano's Crystal Lake 12/07/2017 Letter Form