Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2011007
Status: Active
Facility Name: ISTHA M01 Maintenance Garage
Address: 127th & Cicero on I-294 I-294 MP 12.5 Alsip, IL 60658
County: Cook
Property Parcel: 0000000000
Facility Type: State
Owner Type: State
Green Tag Decal: AA00309
Green Tag Issue Date: 6/9/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Fleet

Owner Details

Owner Name: Illinois State Toll Highway Authority
Owner Address: 2700 Ogden Avenue Downers Grove, IL 60515
Owner Status: Current Owner
Purchase Date: 1/1/1958
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 3/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0007425 Illinois State Toll Highway Authority Current Owner 1/1/1958

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00279-2026UPG Upgrade Approved / Issued 3/4/2026 3/14/2026 9/15/2026 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
15-0975 9/4/2015 Removal Log 00885-2015REM
92-1569 6/29/1992 Removal Log
92-1569 7/17/1992 Removal Log
92-1569 8/7/1992 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-1569 Eligible 9/20/1993 11/23/1993 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/7/1992
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: 7/9/1992 Fee Due: $0.00
Product Date: 1/1/1981

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/17/1992
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: 7/9/1992 Fee Due: $0.00
Product Date: 1/1/1981

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 300 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/27/1992
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1958 Red Tag Issue Date:
Last Used Date: 1/27/1992 Fee Due: $0.00
Product Date: 1/1/1958

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/4/2015
OSFM First Notify Date: 5/5/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 57 Abandoned Date: 1/1/1981
Install Date: 1/1/1958 Red Tag Issue Date:
Last Used Date: 6/1/1981 Fee Due:
Product Date: 1/1/1958

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/4/2015
OSFM First Notify Date: 5/5/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 57 Abandoned Date: 1/1/1981
Install Date: 1/1/1958 Red Tag Issue Date:
Last Used Date: 6/1/1981 Fee Due:
Product Date: 1/1/1958

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 6

Capacity: 300 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/29/1992
OSFM First Notify Date: 1/22/1992 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/29/1992 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 7

Capacity: 10000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 7/1/1992
OSFM First Notify Date: 1/22/1992 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 7/1/1992 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/30/2015
OSFM First Notify Date: 8/3/1993 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 9/14/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/15/1992

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/19/2014 9/19/2015
Leak Detect - Piping Sump Sensor 9/19/2014 9/19/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 9

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/30/2015
OSFM First Notify Date: 8/3/1993 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 9/14/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/15/1992

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/19/2014 9/19/2015
Leak Detect - Piping Sump Sensor 9/19/2014 9/19/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 10

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/10/2012 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/27/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/27/2012

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Other Non-vented check valve Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/6/2025 11/6/2026
Overfill Prev Device Overfill Alarm 12/10/2024 12/10/2027
Overfill Prev Device Overfill Drop Tube Valve 12/10/2024 12/10/2027
Piping Aboveground Not applicable Not applicable
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated 12/10/2024 12/10/2027
Piping Single Wall STP/Tanktop Sump 12/10/2024 12/10/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/10/2024 12/10/2027
Piping Single Wall Transition Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 12/10/2024 12/10/2027
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 11

Capacity: 10000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/10/2012 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/27/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/27/2012

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/6/2025 11/6/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/6/2025 11/6/2026
Overfill Prev Device Overfill Alarm 12/10/2024 12/10/2027
Overfill Prev Device Overfill Drop Tube Valve 12/10/2024 12/10/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 12/10/2024 12/10/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/10/2024 12/10/2027
Spill Contain Device Double Wall Spill Bucket 12/10/2024 12/10/2027
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/14/2024



Tank Number 12

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/12/2015 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 7/28/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/26/2015

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/6/2025 11/6/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 11/6/2025 11/6/2026
Overfill Prev Device Overfill Alarm 12/10/2024 12/10/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 12/10/2024 12/10/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/10/2024 12/10/2027
Spill Contain Device Double Wall Spill Bucket 12/10/2024 12/10/2027
Tank Fiberglass Brine Filled Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 13

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/12/2015 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 7/28/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/26/2015

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/6/2025 11/6/2026
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 11/6/2025 11/6/2026
Overfill Prev Device Overfill Alarm 12/10/2024 12/10/2027
Piping Aboveground Not applicable Not applicable
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 12/10/2024 12/10/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/10/2024 12/10/2027
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Piping Single Wall Transition Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 12/10/2024 12/10/2027
Tank Fiberglass Brine Filled Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/10/2024 12/10/2027
Leak Detect - Piping Sump Sensor with positive shutdown 11/6/2025 11/6/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/10/2024 12/10/2027
Leak Detect - Piping Sump Sensor with positive shutdown 11/6/2025 11/6/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found