Division of Petroleum & Chemical Safety

 
Pay Tank Fees Online Print Detail Page Export to Excel

Facility Details

Facility Number: 2010054
Status: Active
Facility Name: Citgo
Address: 750 Glenwood Dryer Road Glenwood, IL 60425
County: Cook
Property Parcel: 32-11-108-026-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001354
Green Tag Issue Date: 12/12/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Jagtar Singh
Owner Address: 750 Glenwood Dryer Road Glenwood, IL 60425
Owner Status: Current Owner
Purchase Date: 7/1/1998
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/10/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/12/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0028747 Singh, Jagtar Current Owner 7/1/1998
U0003073 Clark Retail Enterprises, Inc. Former Owner 11/22/1988

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00969-2025UPG Upgrade Approved / Issued 7/25/2025 7/28/2025 1/28/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020252011 (Pending)    Issue Date: 8/8/2025    Expiration Date: 10/7/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - All emergency shutoff switches shall be tested annually to verify they shut down all STPs and dispensers. Form can be found at https://sfm.illinois.gov to download and complete.
4, 5 Line interstitial sensor functional test not accomplished (Required annually).
4, 5 Mechanical line leak detector requires annual functional test.
Facility Missing copies of 30 day Walkthrough Inspection Report. - Shall be completed, and documentation maintained on site. 30-Day Walkthrough Inspection form available at https://sfm.illinois.gov/content/dam/soi/en/web/sfm/sfmdocuments/documents/30-day-walkthrough-inspection-report.pdf (No documentation since March of 2025)
4, 5 Overfill prevention equipment inspection(s) not completed (Required every 3 years).
Facility Submit Notification Form For Ownership Change - The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. Select “New Owner” as the type of notification form.
4, 5 Tank interstitial sensor functional test not accomplished (Required annually).
4, 5 Triennial spill prevention equipment testing not completed.
4, 5 Triennial testing for qualifying piping containment sump not completed (Required every 3 years).

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
99-1943 8/17/1999 Removal Log 02297-1999REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
95-0268 Eligible 5/16/1995 6/1/1995 $10,000
Pay Tank Fees Online

Tank Information

Tank Number Capacity Product Status Regulated Status Red Tag Issued Fee Due Abandon/Removal Date
1 7500 Gasoline Removed Federal $0.00 08/17/1999 - REM
2 7500 Gasoline Removed Federal $0.00 08/17/1999 - REM
3 7500 Gasoline Removed Federal $0.00 08/17/1999 - REM
4 8000 Gasoline - Regular Currently in use Federal $0.00
5 8000 Gasoline - Premium Currently in use Federal $0.00

Dispenser Information

Name\ID Status
1/2 Active
3/4 Active
5/6 Active

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2010054 Citgo Glenwood 07/25/2025 Letter Form