Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2010044
Status: Inactive
Facility Name: Clark
Address: 16836 Oak Park Avenue Tinley Park, IL 60477
County: Cook
Property Parcel: 28-30-107-027-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: N001307
Green Tag Issue Date: 1/18/2012
Green Tag Expiration Date: 12/31/2014

Owner Details

Owner Name: Prime Petroleum
Owner Address: 16836 Oak Park Avenue Tinley Park, IL 60477
Owner Status: Current Owner
Purchase Date: 8/20/2003
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/14/2013

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/18/2012 12/31/2014

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0031588 Prime Petroleum Current Owner 8/20/2003
U0023845 Clark Refining & Marketing Inc Former Owner 11/22/1988
U0029789 Clark Retail Enterprises, Inc. Former Owner
U0028787 Clark Retail Enterprises, Inc., Former Owner
U0024983 Clark Refining & Marketing, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020140749 (Formal)    Issue Date: 3/13/2014    Expiration Date: 5/12/2014    View NOV Form

Tanks Violations
1, 2 Annual line precision and mechanical line leak detector functional test not completed.
Facility Financial responsibility must be reported yearly
Facility Missing copies of current testing certificates for operator training
1, 2 Piping sacrificial anode system not tested (required every 3 years).
1, 2 Required monthly tank leak test records not available.
Facility Submit Notification Form for Facility Information Change
1, 2 Submit Notification Form For Tank Status Change
1, 2 Tank internal lining inspection past due (Required every 5 years).

NOV Number: E0020150366 (Formal)    Issue Date: 2/20/2015    Expiration Date: 4/21/2015    View NOV Form

Tanks Violations
Facility Financial responsibility must be reported yearly
1, 2 Remove tank(s) - Corrosion Protection not Maintained
1, 2 Remove tank(s) - Single-Walled, Over 30 Years Old and OOS Over One Year
1, 2 Submit Notification Form For Tank Status Change
1, 2 Tank internal lining inspection past due (Required every 5 years).

NOV Number: E0020161200 (Referred to AG)    Issue Date: 4/19/2016    Expiration Date: 6/18/2016    View NOV Form

Tanks Violations
Facility Financial responsibility must be reported yearly
1, 2 Remove tank(s) - Corrosion Protection not Maintained
1, 2 Remove tank(s) - Single-Walled, Over 30 Years Old and OOS Over One Year
Facility Submit Notification Form For Ownership Change
1, 2 Submit Notification Form For Tank Status Change

NOV Number: E0020161204 (Referred to AG)    Issue Date: 4/19/2016    Expiration Date: 6/18/2016    View NOV Form

Tanks Violations
Facility Financial responsibility must be reported yearly
1, 2 Remove tank(s) - Corrosion Protection not Maintained
1, 2 Remove tank(s) - Single-Walled, Over 30 Years Old and OOS Over One Year
Facility Submit Notification Form For Ownership Change
1, 2 Submit Notification Form For Tank Status Change

NOV Number: E0020161205 (Formal)    Issue Date: 4/19/2016    Expiration Date: 6/18/2016    View NOV Form

Tanks Violations
Facility Financial responsibility must be reported yearly
1, 2 Remove tank(s) - Corrosion Protection not Maintained
1, 2 Remove tank(s) - Single-Walled, Over 30 Years Old and OOS Over One Year
Facility Submit Notification Form For Ownership Change
1, 2 Submit Notification Form For Tank Status Change

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
95-0363 Eligible 4/26/1995 5/11/1995 $10,000
95-0363 Eligible 4/29/2003 5/12/2003 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/1987 Abandoned Material:
Current Age: 56 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date: 5/14/2014
Last Used Date: 12/31/2013 Fee Due: $0.00
Product Date: 1/1/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 7/17/2008 7/17/2013
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/29/2011 7/29/2012
Leak Detect - Tank Automatic Tank Gauging Arizona Instruments Encompass
Overfill Prev Device Ball Float Vent Valve
Piping Fiberglass Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/1987 Abandoned Material:
Current Age: 56 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date: 3/19/2025
Last Used Date: 12/31/2013 Fee Due: $0.00
Product Date: 1/1/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 7/17/2008 7/17/2013
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/29/2011 7/29/2012
Leak Detect - Tank Automatic Tank Gauging Arizona Instruments Encompass
Overfill Prev Device Ball Float Vent Valve
Piping Fiberglass Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found