Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2010026
Status: Active
Facility Name: GoLo Gas Station
Address: 330 W. Chicago Ave. Oak Park, IL 60302
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003092
Green Tag Issue Date: 8/29/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Hargobind, Inc.
Owner Address: 100 W. Chicago Ave. Oak Park, IL 60302
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 2/16/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/29/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036187 Hargobind, Inc. Current Owner
U0030478 Reddy, Ramachandra Former Owner 11/1/2004
U0029789 Clark Retail Enterprises, Inc. Former Owner 11/22/1988
U0003073 Clark Retail Enterprises, Inc. Former Owner 11/22/1988
U0037798 Singh, Daljit Former Owner
U0028787 Clark Retail Enterprises, Inc., Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251937 (Pending)    Issue Date: 8/4/2025    Expiration Date: 10/3/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
3, 4 Annual leak detection certification not completed (Required annually).
3, 4 Annual line precision and mechanical line leak detector functional test not completed.
Facility Missing copies of Annual Walkthrough Inspection Report.
Facility Missing list of designated Class A/B & C Operators - ALL CLERKS NEED TO HAVE A "C" CERTIFICATE
3, 4 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - TEST IS DUE BY OCTOBER 2025
3, 4 Triennial spill prevention equipment testing not completed. - TEST IS DUE OCT. 2025

NOV Number: E0020251942 (Pending)    Issue Date: 8/4/2025    Expiration Date: 10/3/2025    View NOV Form

Tanks Violations
Facility Fire Extinguishers - 2 4A:60BC extinguishers not provided, 1 at or near control station and 1 in the dispensing areas - Your fire extinguishers are too small they need to be 4A:60BC ( 10 #s )
Facility Miscellaneous - Blocked with lottery tickets

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
97-1663 9/8/1997 Removal Log
971663 9/8/1997 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
97-1663 Eligible 12/5/1997 1/6/1998 $10,000
97-1663 Eligible 5/15/2003 6/16/2003 $10,000
97-1663 Eligible 8/31/2015 9/3/2015 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/8/1997
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: 9/8/1997 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/8/1997
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: 9/8/1997 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/5/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 9/11/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/11/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/15/2024 6/15/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/11/2025 8/11/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 8/11/2025 8/11/2026
Overfill Prev Device Overfill Drop Tube Valve 8/11/2025 8/11/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/11/2025 8/11/2028
Tank Fiberglass Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 8/11/2025



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/5/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 9/11/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/11/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/15/2024 6/15/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/11/2025 8/11/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 8/11/2025 8/11/2026
Overfill Prev Device Overfill Drop Tube Valve 8/11/2025 8/11/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/11/2025 8/11/2028
Tank Fiberglass Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 8/11/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found