Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0040977 |
18259 Crawford Property, LLC |
Current Owner |
3/21/2023 |
| U0040301 |
Majid RE, LLC |
Former Owner |
8/7/2020 |
| U0039542 |
Ketankumar K Soni |
Former Owner |
9/6/2018 |
| U0031904 |
Reddy, Ramachandra |
Former Owner |
3/5/2004 |
| U0008842 |
Lake Shore Petroleum Corporation |
Former Owner |
6/7/1994 |
| U0010471 |
ExxonMobil Oil Corporation |
Former Owner |
12/31/1967 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 2024-0531 |
7/19/2024 |
Abandonment Log |
00799-2024ABN |
| N/A |
10/4/2023 |
Removal Log |
00982-2023REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 87-0553 |
Eligible |
4/12/1994
|
4/28/1994
|
$50,000
|
|
| 90-0279 |
Returned |
4/30/2001
|
5/17/2001
|
$Not Selected
|
|
| 90-0279 |
Eligible |
5/23/2001
|
6/14/2001
|
$10,000
|
|
Tank Number 1
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
43 |
|
Abandoned Date: |
|
| Install Date: |
11/24/1982 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
6/1/2026 |
6/1/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Gilbarco EMC with CSLD |
6/1/2026 |
6/1/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/1/2026 |
6/1/2029 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
7/8/2024 |
7/8/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
7/8/2024 |
7/8/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/1/2026 |
6/1/2029 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
6/1/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
8/25/2023
|
Tank Number 2
| Capacity: |
6000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Abandoned in place |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
42 |
|
Abandoned Date: |
7/19/2024 |
| Install Date: |
8/16/1983 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
5/1/2023 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
7/23/2020 |
5/9/2023 |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/7/2021 |
9/7/2022 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Gilbarco EMC with CSLD |
4/19/2023 |
4/19/2024 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
7/25/2019 |
7/25/2022 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall Transition Sump |
5/8/2023 |
5/8/2026 |
Leak Detect - Piping
|
Sump Sensor |
5/8/2023 |
5/8/2026 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
5/8/2023 |
5/8/2026 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
9/7/2021
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Fail
|
1/19/2023
|
Tank Number 3
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
42 |
|
Abandoned Date: |
|
| Install Date: |
8/16/1983 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
6/1/2026 |
6/1/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Gilbarco EMC with CSLD |
6/1/2026 |
6/1/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/1/2026 |
6/1/2029 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
7/8/2024 |
7/8/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
7/8/2024 |
7/8/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/1/2026 |
6/1/2029 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
6/1/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
8/25/2023
|
Tank Number 4
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
42 |
|
Abandoned Date: |
|
| Install Date: |
8/16/1983 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
6/1/2026 |
6/1/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Gilbarco EMC with CSLD |
6/1/2026 |
6/1/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/1/2026 |
6/1/2029 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
7/8/2024 |
7/8/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
7/8/2024 |
7/8/2027 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
6/1/2026 |
6/1/2029 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
6/1/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
7/8/2024
|
Tank Number 5
| Capacity: |
550 |
|
Petroleum Use: |
|
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
11/13/1989 |
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
25 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
11/11/1989 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 6
| Capacity: |
1000 |
|
Petroleum Use: |
None |
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/22/2002 |
|
OSFM
First Notify Date: |
10/22/1991 |
|
Abandoned Material: |
|
| Current Age: |
12 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1990 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 7
| Capacity: |
550 |
|
Petroleum Use: |
None |
| Product: |
Waste Oil |
|
CERCLA Substance: |
|
| Status: |
Does Not Exist |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
8/30/2023 |
|
Abandoned Material: |
|
| Current Age: |
|
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/2
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
Not applicable
|
Not applicable
|
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable
|
Not applicable
|
Name\ID 3/4
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
Not applicable
|
Not applicable
|
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable
|
Not applicable
|
Name\ID 5/6
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
Not applicable
|
Not applicable
|
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable
|
Not applicable
|
Name\ID 7/8
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
Not applicable
|
Not applicable
|
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable
|
Not applicable
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found