Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2009039
Status: Active
Facility Name: Mobil
Address: 810 N. Roselle Rd. Hoffman Estates, IL 60172
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000238
Green Tag Issue Date: 1/18/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: 810 Roselle Real Estate, Inc.
Owner Address: 810 N. Roselle Rd. Hoffman Estates, IL 60169
Owner Status: Current Owner
Purchase Date: 1/11/2018
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/24/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/18/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039065 810 Roselle Real Estate, Inc. Current Owner 1/11/2018
U0028268 Shah Enterprises, Inc. Former Owner 8/11/1994
U0010471 Exxon Mobil Oil Corporation Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
90-3808 Eligible 5/20/1994 6/13/1994 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 8/1/1987
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/1/1987 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 8/1/1987
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/1/1987 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 8/1/1987
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/1/1987 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 8/1/1987
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/1/1987 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/19/1988 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 5/20/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/21/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/21/2025 4/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/21/2025 4/21/2026
Overfill Prev Device Ball Float Vent Valve OPW 53VML 5/1/2024 5/1/2027
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/1/2024 5/1/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/17/2020
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test (Piping) Pass 7/11/2022



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/19/1988 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 5/20/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/21/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/21/2025 4/21/2026
Overfill Prev Device Overfill Drop Tube Valve 5/1/2024 5/1/2027
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 5/1/2024 5/1/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/17/2020
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test (Piping) Pass 7/11/2022
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Fail 5/17/2022



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/19/1988 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 5/20/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/21/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/19/2022 7/19/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/21/2025 4/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/21/2025 4/21/2026
Overfill Prev Device Ball Float Vent Valve OPW 53VML 5/1/2024 5/1/2027
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/1/2024 5/1/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/17/2020
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test (Piping) Pass 7/11/2022
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 5/18/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found