Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2009009
Status: Active
Facility Name: 76 Icon Legacy Group
Address: 1401 River Oaks Drive Calumet City, IL 60409
County: Cook
Property Parcel: 29-24-200-005-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: BB00314
Green Tag Issue Date: 4/3/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Self Service

Owner Details

Owner Name: Peak Point Petro Group Inc.
Owner Address: 1401 River Oaks Drive Calumet City, IL 60409
Owner Status: Current Owner
Purchase Date: 5/9/2025
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/3/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041748 Peak Point Petro Group Inc. Current Owner 5/9/2025
U0034093 Esquire Petroleum, LLC Former Owner 2/14/2007
U0010471 ExxonMobil Oil Corporation Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00312-2026CAT Cathodic Protection Approved / Issued 3/23/2026 3/23/2026 9/23/2026 Documents
01699-2025UPG Upgrade Approved / Issued 12/31/2025 12/31/2025 6/30/2026 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
97-2404 Eligible 11/8/2001 11/15/2001 $10,000
06-1452 Eligible 6/5/2007 7/2/2007 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 8/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/3/2026 4/3/2029
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/2/2026 2/2/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/2/2026 2/2/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 2/2/2026 2/2/2029
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 2/2/2026 2/2/2029
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/2/2026 2/2/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 2/2/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/14/2026



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 8/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/6/2023 9/6/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/2/2026 2/2/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/2/2026 2/2/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 2/2/2026 2/2/2029
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 2/2/2026 2/2/2029
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/2/2026 2/2/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 2/2/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/14/2026



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 8/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/6/2023 9/6/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/2/2026 2/2/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/2/2026 2/2/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 2/2/2026 2/2/2029
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 2/2/2026 2/2/2029
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Double Wall Spill Bucket 2/2/2026 2/2/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 2/2/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/14/2026



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/19/1988 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 8/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/6/2023 9/6/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/27/2024 3/27/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/2/2026 2/2/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/2/2026 2/2/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 2/2/2026 2/2/2029
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 2/2/2026 2/2/2029
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/2/2026 2/2/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 2/2/2026
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/14/2026

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found