Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2008992
Status: Active
Facility Name: I-57 Fuel Mart (Gulf)
Address: 9901 S. Halsted Chicago, IL 60628
County: Cook
Property Parcel: 25-09-300-057-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002480
Green Tag Issue Date: 9/4/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Parkland Enterprises, Inc.
Owner Address: 8603 W. 142nd Street Orland Park, IL 60462
Owner Status: Current Owner
Purchase Date: 7/15/2016
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 1/23/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037068 Parkland Enterprises, Inc. Current Owner 7/15/2016
U0033024 JMJ Mobil Former Owner 11/1/2004
U0010471 ExxonMobil Oil Corporation Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00148-2026UPG Upgrade Approved / Issued 2/7/2026 2/10/2026 8/11/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020261102 (Pending)    Issue Date: 4/23/2026    Expiration Date: 6/22/2026    View NOV Form

Tanks Violations
6, 7, 8 Dispensers - the following hoses or breakaways are missing or actively leaking and require immediate replacement (bagged at inspection)

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-0630 Eligible 4/10/2000 4/25/2000 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/1/1986
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/1/1986
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/1/1986
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/1/1986
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/1/1986
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/19/1988 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/6/2026 4/6/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/6/2026 4/6/2027
Overfill Prev Device Overfill Drop Tube Valve 11/27/2025 11/27/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/9/2026 2/9/2029
Leak Detect - Piping Sump Sensor 4/6/2026 4/6/2027
Spill Contain Device Single Wall Spill Bucket 11/28/2025 11/28/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 4/6/2026



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/19/1988 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/6/2026 4/6/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/6/2026 4/6/2027
Overfill Prev Device Overfill Drop Tube Valve 2/9/2026 2/9/2029
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/9/2026 2/9/2029
Leak Detect - Piping Sump Sensor 4/6/2026 4/6/2027
Spill Contain Device Double Wall Spill Bucket 2/9/2026 2/9/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 4/6/2026



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/19/1988 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/6/2026 4/6/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/6/2026 4/6/2027
Overfill Prev Device Overfill Drop Tube Valve 11/27/2025 11/27/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/9/2026 2/9/2029
Leak Detect - Piping Sump Sensor 4/6/2026 4/6/2027
Spill Contain Device Single Wall Spill Bucket 11/27/2025 11/27/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 4/6/2026



Tank Number 9

Capacity: 10000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/19/1988 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/6/2026 4/6/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/6/2026 4/6/2027
Overfill Prev Device Overfill Drop Tube Valve 11/27/2025 11/27/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/9/2026 2/9/2029
Leak Detect - Piping Sump Sensor 4/6/2026 4/6/2027
Spill Contain Device Single Wall Spill Bucket 11/27/2025 11/27/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 4/6/2026

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/9/2026 2/9/2029
Leak Detect - Piping Sump Sensor 4/6/2026 4/6/2027



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/9/2026 2/9/2029
Leak Detect - Piping Sump Sensor 4/6/2026 4/6/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/9/2026 2/9/2029
Leak Detect - Piping Sump Sensor 4/6/2026 4/6/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/9/2026 2/9/2029
Leak Detect - Piping Sump Sensor 4/6/2026 4/6/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/9/2026 2/9/2029
Leak Detect - Piping Sump Sensor 4/6/2026 4/6/2027



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/9/2026 2/9/2029
Leak Detect - Piping Sump Sensor 4/6/2026 4/6/2027

MFD Motorfuel Dispensing Forms