Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2008830
Status: Closed
Facility Name: Bob Rohrman Auto Group
Address: 100 Old Skokie Rd. Park City, IL 60085
County: Lake
Property Parcel:
Facility Type: Auto Dealer
Owner Type: Private
Green Tag Decal: F001944
Green Tag Issue Date: 9/13/2004
Green Tag Expire Date: 12/31/2007
MFD Type: N/A

Owner Details

Owner Name: Arlington Lexus, Inc.
Owner Address: 1285 Dundee Road Palatine, IL 60074
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/4/2013

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0033229 Arlington Lexus, Inc. Current Owner
U0027878 Robert V Rohrman Former Owner 7/1/1998
U0013221 Marquardt Motor Sales Inc Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/1/1990
OSFM First Notify Date: 4/29/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/13/1988
OSFM First Notify Date: 4/29/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/13/1988 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Ethylene Glycol CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/13/1988
OSFM First Notify Date: 4/29/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/13/1988 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/13/1988
OSFM First Notify Date: 4/29/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/13/1988 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/27/2012
OSFM First Notify Date: 5/28/1997 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 2/1/1990 Red Tag Issue Date:
Last Used Date: 1/15/2005 Fee Due: $0.00
Product Date: 3/1/1990

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Tracer Elements Vapor Monitoring Tracer Research Corp. Tracer Tite No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Manhole Field Constructed No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found