Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2008754
Status: Active
Facility Name: Future HT HQ
Address: 580 S Wolf Rd
PO Box 129
Des Plaines, IL 60018
County: Cook
Property Parcel: 09-18-400-006-0000
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Z004099
Green Tag Issue Date: 10/22/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: 580 S. Wolf Rd, LLC
Owner Address: 1344 Indigo Drive
Mount Prospect, IL 60056
Owner Status: Current Owner
Purchase Date: 8/2/2022
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/31/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 10/22/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041036 580 S. Wolf Rd, LLC Current Owner 8/2/2022
U0010204 Meyer Material Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020240067 (Referred to Legal)    Issue Date: 1/8/2024    Expiration Date: 3/8/2024    View NOV Form

Tanks Violation
7 Perform a site assessment - Owners or operators must designate and submit to OSFM, on OSFM forms (titled “Site Assessment Results” form with a “contamination” or “no contamination” results indicating whether a release has occurred, along with associated lab results.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
98-3008 12/8/1998 Removal Log 2457-98
N/A 11/9/2023 Removal Log 01251-2023REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/24/1992
OSFM First Notify Date: 4/21/1986 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 4/1/1974 Red Tag Issue Date:
Last Used Date: 3/1/1990 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/8/1998
OSFM First Notify Date: 4/21/1986 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/7/1998 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/24/1992
OSFM First Notify Date: 4/21/1986 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 4/1/1975 Red Tag Issue Date:
Last Used Date: 7/1/1992 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1988
OSFM First Notify Date: 4/21/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 4/1/1966 Red Tag Issue Date:
Last Used Date: 4/1/1974 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/24/1992
OSFM First Notify Date: 9/25/1992 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 4/1/1960 Red Tag Issue Date:
Last Used Date: 4/1/1972 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 550 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/24/1992
OSFM First Notify Date: 9/25/1992 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 4/1/1960 Red Tag Issue Date:
Last Used Date: 4/1/1972 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 8000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 11/9/2023
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/14/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 5/2/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/8/2024 10/8/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 10/8/2024 10/8/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/8/2024 10/8/2025
Overfill Prev Device Overfill Drop Tube Valve 8/2/2024 8/2/2027
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 5/17/2024 5/17/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2024 10/8/2025
Spill Contain Device Double Wall Spill Bucket 5/17/2024 5/17/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 10/7/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/7/2024

Dispenser Information



Name\ID 1 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/17/2024 5/17/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2024 10/8/2025



Name\ID 1 Satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/17/2024 5/17/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2024 10/8/2025



Name\ID 2 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/17/2024 5/17/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2024 10/8/2025



Name\ID 2 Satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/17/2024 5/17/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/8/2024 10/8/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2008754 Future HT HQ Des Plaines 07/12/2024 Letter Form