Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2008128
Status: Active
Facility Name: Rawlings Towing
Address: 600 W. Irving Park
Bensenville, IL 60106
County: Du Page
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000203
Green Tag Issue Date: 5/22/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Rawlings Towing
Owner Address: 600 W. Irving Park
Bensenville, IL 60106
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/29/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/22/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0012485 Rawlings Towing Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
00-1510 8/9/2000 Removal Log 01092-2000REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
00-1510 Eligible 8/28/2000 9/11/2000 $15,000
03-1200 Eligible 8/19/2003 8/25/2003 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/27/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/24/2023 8/24/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/24/2023 8/24/2024
Overfill Prev Device Overfill Drop Tube Valve 8/24/2023 8/24/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/28/2021 9/28/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 8/24/2023
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 7/10/2010



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/27/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/24/2023 8/24/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/24/2023 8/24/2024
Overfill Prev Device Overfill Drop Tube Valve 8/24/2023 8/24/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/28/2021 9/28/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 8/24/2023
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 7/10/2010



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/27/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/24/2023 8/24/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/24/2023 8/24/2024
Overfill Prev Device Overfill Drop Tube Valve 8/24/2023 8/24/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/28/2021 9/28/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 8/24/2023
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 7/10/2010



Tank Number 4

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/9/2000
OSFM First Notify Date: 4/27/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 12/20/1998 Fee Due: $0.00
Product Date: 1/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/18/1990 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 12/13/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/24/2023 8/24/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/24/2023 8/24/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/24/2023 8/24/2024
Overfill Prev Device Overfill Drop Tube Valve 8/24/2023 8/24/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 9/28/2021 9/28/2024
Leak Detect - Piping Sump Sensor 8/24/2023 8/24/2024
Spill Contain Device Single Wall Spill Bucket 9/28/2021 9/28/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 8/24/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found