Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2007979
Status: Active
Facility Name: Greater Chicago Truck Plaza
Address: 510 South Bolingbrook Drive Bolingbrook, IL 60440
County: Will
Property Parcel: 12-02-23-100-010-000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01998
Green Tag Issue Date: 8/15/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: I-55 Truckstop Properties LLC
Owner Address: 510 S. Bolingbrook Drive Bolingbrook, IL 60440
Owner Status: Current Owner
Purchase Date: 4/1/2001
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/19/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/15/2025 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0029954 I-55 Truckstop Properties LLC Current Owner 4/1/2001
U0030951 Puthusseril, John Former Owner 1/22/2001
U0026726 TA Operating, LLC Former Owner 11/23/1992
U0022252 National Auto Truckstops Inc Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00942-2025UPG Upgrade Approved / Issued 7/21/2025 7/21/2025 1/21/2026 Documents
01168-2025UPG Upgrade Approved / Issued 9/4/2025 9/4/2025 3/4/2026 Documents
01286-2025UPG Upgrade Approved / Issued 9/24/2025 10/1/2025 4/1/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020252117 (Referred to Legal)    Issue Date: 8/15/2025    Expiration Date: 10/14/2025    View NOV Form

Tanks Violations
16 Remove single-wall tank(s) - Out of Service greater than 5 Years

NOV Number: E0020252795 (Pending)    Issue Date: 10/21/2025    Expiration Date: 12/20/2025    View NOV Form

Tanks Violations
Facility Due to outstanding Motor Fuel Dispensing violation(s) at this facility, after 60 days from the issuance date of this Notice of Violation, and in the absence of full compliance, all tanks shall be red tagged. - NOV issued 8/15/2025 to remove tank 16.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
02-1264 10/23/2002 Removal Log 01624-2002REM
961412 7/31/1998 Abandonment Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-1200 Eligible 11/24/1993 12/14/1993 $10,000
02-1264 Returned 9/17/2002 10/7/2002 $Not Selected
02-1264 Eligible 11/22/2002 1/8/2003 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/18/1990
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 3000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: State Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 57 Abandoned Date: 9/23/1991
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 12/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code: MX8006619
Regulated Status: Federal Removed Date: 10/23/2002
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 3/20/2002 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/18/1990
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 3000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: State Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 32 Abandoned Date: 9/23/1991
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code: MX8006619
Regulated Status: Federal Removed Date: 10/23/2002
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 3/20/2002 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code: MX8006619
Regulated Status: Federal Removed Date: 10/23/2002
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 3/20/2002 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code: 68476346
Regulated Status: Federal Removed Date: 10/23/2002
OSFM First Notify Date: 4/14/1986 Abandoned Material: Tripolymer Foam
Current Age: 34 Abandoned Date: 8/13/1998
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 1/31/1997 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code: 68476346
Regulated Status: Federal Removed Date: 10/23/2002
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 3/20/2002 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code: 68476346
Regulated Status: Federal Removed Date: 10/23/2002
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 3/20/2002 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code: 68476346
Regulated Status: Federal Removed Date: 10/23/2002
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 3/20/2002 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 12

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/13/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 3/15/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/16/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 5/7/2025 5/7/2026
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/25/2023 6/25/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/15/2024



Tank Number 13

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/2/2002 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 12/11/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/25/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/30/2025 6/30/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/30/2025 6/30/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 6/30/2025 6/30/2026
Overfill Prev Device Overfill Drop Tube Valve 3/27/2025 3/27/2028
Piping Flexible Double Wall A.P.T. Poly Tech S175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026
Piping Single Wall STP/Tanktop Sump 6/25/2023 6/25/2026
Leak Detect - Piping Non-Discriminating Sump Sensor 12/11/2016 12/11/2017
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026
Spill Contain Device Double Wall Spill Bucket 6/25/2023 6/25/2026
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech S175SC Precision Test (Piping) Pass 5/7/2025
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Pass 1/8/2020



Tank Number 14

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/2/2002 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 12/11/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/25/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/30/2025 6/30/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/30/2025 6/30/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 6/30/2025 6/30/2026
Overfill Prev Device Overfill Drop Tube Valve 3/27/2025 3/27/2028
Piping Flexible Double Wall A.P.T. Poly Tech S175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/25/2023 6/25/2026
Leak Detect - Piping Non-Discriminating Sump Sensor 12/11/2016 12/11/2017
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026
Piping Single Wall STP/Tanktop Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026
Spill Contain Device Double Wall Spill Bucket 6/25/2023 6/25/2026
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech S175SC Precision Test (Piping) Pass 5/7/2025
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Pass 1/8/2020



Tank Number 15

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/2/2002 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 12/11/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/25/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/7/2025 5/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 5/7/2025 5/7/2026
Overfill Prev Device Overfill Drop Tube Valve 6/25/2023 6/25/2026
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Single Wall STP/Tanktop Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor 5/7/2025 5/7/2026
Spill Contain Device Single Wall Spill Bucket 6/25/2023 6/25/2026
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 5/7/2025



Tank Number 16

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/2/2002 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 12/11/2001 Red Tag Issue Date: 1/30/2020
Last Used Date: 8/4/2020 Fee Due: $0.00
Product Date: 2/25/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/15/2024 4/15/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 4/15/2024 4/15/2025
Overfill Prev Device Overfill Drop Tube Valve 4/8/2020 4/8/2023
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Double Wall STP/Tanktop Sump 6/25/2023 6/25/2026
Piping Single Wall STP/Tanktop Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor 4/15/2024 4/15/2025
Spill Contain Device Single Wall Spill Bucket 6/25/2023 6/25/2026
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 4/15/2024
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Pass 4/1/2020
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 5/21/2007



Tank Number 17

Capacity: 12000 Petroleum Use: None
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/3/2014 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 8/16/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/30/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/7/2025 5/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/8/2025 8/8/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/8/2025 8/8/2026
Overfill Prev Device Overfill Drop Tube Valve 7/23/2025 7/23/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 8/8/2025 8/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/8/2025 8/8/2026
Spill Contain Device Double Wall Spill Bucket 7/23/2025 7/23/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/7/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 5/7/2025



Tank Number 18

Capacity: 8000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 1/3/2014 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 8/16/2012 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 11/30/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/7/2025 7/7/2026



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor 5/7/2025 5/7/2026



Name\ID 10 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026



Name\ID 2 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026



Name\ID 3 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor 5/7/2025 5/7/2026



Name\ID 4 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026



Name\ID 5 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor 5/7/2025 5/7/2026



Name\ID 6 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026



Name\ID 7 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor 5/7/2025 5/7/2026



Name\ID 8 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026



Name\ID 9 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/25/2023 6/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2025 6/30/2026



Name\ID B-99

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2025 8/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/8/2025 8/8/2026

MFD Motorfuel Dispensing Forms