Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2006982
Status: Active
Facility Name: Premier Petroleum, LLC
Address: 7000 Kingery Hwy
Willowbrook, IL 60514
County: Du Page
Property Parcel: 09-23-310-024
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003179
Green Tag Issue Date: 1/9/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Maqpoon Management, Inc.
Owner Address: 7000 S. Route 83
Willowbrook, IL 60527
Owner Status: Current Owner
Purchase Date: 5/21/2019
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 12/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/19/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040247 Maqpoon Management, Inc. Current Owner 5/21/2019
U0035735 True North Energy, LLC Former Owner 3/8/2010
U0027449 Equilon Enterprises, LLC Former Owner 1/1/1984
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020241337 (Pending)    Issue Date: 5/9/2024    Expiration Date: 7/8/2024    View NOV Form

Tanks Deficiency
1 Miscellaneous - Tank Failed Precision Test: Vent Line in Multi-port Containment is Leaking.
2, 3 Miscellaneous - Precision Tank Test inconclusive due to all tanks be connected through vapor recovery and vent on Tank 1 leaking

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
90-0130 Eligible 5/20/2003 6/23/2003 $10,000
90-0130 Eligible 10/5/2011 12/4/2011 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/21/2023 9/21/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 9/21/2023 9/21/2024
Overfill Prev Device Overfill Drop Tube Valve 1/29/2021 1/29/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/2/2021 10/2/2024
Leak Detect - Piping Discriminating Sump Sensor 3/6/2019 3/6/2020
Leak Detect - Piping Non-Discriminating Sump Sensor 9/30/2020 9/30/2021
Leak Detect - Piping Sump Sensor 9/21/2023 9/21/2024
Spill Contain Device Single Wall Spill Bucket 10/2/2021 10/2/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 9/21/2023
Tank Fiberglass Single Wall Precision Test (Tank) Fail 9/21/2023



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 9/21/2023 9/21/2024
Overfill Prev Device Overfill Drop Tube Valve 1/29/2021 1/29/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/2/2021 10/2/2024
Leak Detect - Piping Discriminating Sump Sensor 3/6/2019 3/6/2020
Leak Detect - Piping Non-Discriminating Sump Sensor 9/30/2020 9/30/2021
Leak Detect - Piping Sump Sensor 9/21/2023 9/21/2024
Spill Contain Device Single Wall Spill Bucket 10/2/2021 10/2/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 9/21/2023
Tank Fiberglass Single Wall Precision Test (Tank) Fail 9/21/2023



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/21/2023 9/21/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 9/21/2023 9/21/2024
Overfill Prev Device Overfill Drop Tube Valve 1/29/2021 1/29/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/2/2021 10/2/2024
Leak Detect - Piping Discriminating Sump Sensor 3/6/2019 3/6/2020
Leak Detect - Piping Non-Discriminating Sump Sensor 9/30/2020 9/30/2021
Leak Detect - Piping Sump Sensor 9/21/2023 9/21/2024
Spill Contain Device Single Wall Spill Bucket 10/2/2021 10/2/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 9/21/2023
Tank Fiberglass Single Wall Precision Test (Tank) Fail 9/21/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/2/2021 10/2/2024
Leak Detect - Piping Stand Alone Sump Sensor 9/21/2023 9/21/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/2/2021 10/2/2024
Leak Detect - Piping Stand Alone Sump Sensor 9/21/2023 9/21/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/2/2021 10/2/2024
Leak Detect - Piping Stand Alone Sump Sensor 9/21/2023 9/21/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/2/2021 10/2/2024
Leak Detect - Piping Stand Alone Sump Sensor 9/21/2023 9/21/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/2/2021 10/2/2024
Leak Detect - Piping Stand Alone Sump Sensor 9/21/2023 9/21/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/2/2021 10/2/2024
Leak Detect - Piping Stand Alone Sump Sensor 12/19/2023 12/19/2024

MFD Motorfuel Dispensing Forms

No Forms Found